Output Line Source
Off
Software Controlled
Pulse On: Start of Frame
Pulse on: Start of Line
Pulse On: Start of
Exposure
Pulse On: End of
Exposure
Pulse on: Start of
Readout
Pulse On: End of Readout
Pulse On: Valid Frame
Trigger
Pulse On: Valid Line
Trigger
Pulse On: Invalid Frame
Trigger
Pulse On: Start of
Acquisition
Pulse On: End of
Acquisition
Pulse On: Timer 1 End
Pulse On: Timer 2 End
Pulse On: Counter 1 End
Pulse On: Counter 2 End
Pulse on: Input Line 1
Event
Pulse on: Input Line 2
Event
Pulse on: Input Line 3
Event
Pulse on: Input Line 4
Event
Pulse On: Software
Command
Frame Trigger
Frame Valid
Exposure Active
Line Valid
Smart Strobe Active
Linea GigE Series Camera
cP_OutputLineSource
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofLine
PulseOnStartofExposure
PulseOnEndofExposure
PulseOnStartofReadout
PulseOnEndofReadout
PulseOnValidFrameTrigger
PulseOnValidLineTrigger
PulseOnInvalidFrameTrigger
PulseOnStartofAcquisition
PulseOnEndofAcquisition
PulseOnTimer1End
PulseOnTimer2End
PulseOnCounter1End
PulseOnCounter2End
PulseOnInput1
PulseOnInput2
PulseOnInput3
PulseOnInput4
PulseOnSoftwareCmd
FrameTriggerActive
FrameActive
ExposureActive
ReadoutActive
SmartStrobeActive
Line5
Index of the physical line and associated I/O
control block to use.
Line6
Index of the physical line and associated I/O
control block to use.
Selects which internal signal, or event driven
pulse, or software control state to output on the
selected output line.
Off
Line output is Open
The OutputLineValue feature changes the state of
the output.
Generate a pulse on the start of the Frame Active
event.
Generate a pulse on the start of the Line Active
Generate a pulse on the ExposureStart event. This
option is typically used to trigger a strobe light.
Generate a pulse on the ExposureEnd event. This
option is typically used to trigger a strobe light.
Generate a pulse on the ReadoutStart event.
Generate a pulse on the ReadoutEnd event.
Generate a pulse on the FrameTrigger event.
Generate a pulse on the LineTrigger event.
Generate a pulse on the Invalid FrameTrigger
event.
Generate a pulse when the AcquisitionStart event
occurs.
Generate a pulse when the AcquisitionStop event
occurs.
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the TimerEnd 2 event.
Generate a pulse on the CounterEnd event.
Generate a pulse on the CounterEnd 2 event.
Generate a pulse on the Input signal 1 event.
Generate a pulse on the Input signal 2 event.
Generate a pulse on the Input signal 3 event.
Generate a pulse on the Input signal 4 event.
Generate a pulse on the Input of a Software
Command
Generate a signal that is active when the frame
trigger is active
Generate a signal that is active when the Frame
valid is active
Generate a signal that is active when the Exposure
is active
Generate a signal that is active when the line valid
is active
Generate a signal that is active when the Readout
or the ExposureDelay are active. The smart strobe
only works when triggerLineCount is greater than 1