Table 6 Dc Characteristics - Nokia RX-44 Service Manual

Table of Contents

Advertisement

RX-44
General Information
Signal
Min
Battery
voltage
(active)
Charger
-0.3
input
voltage
Signal
Min
VBAT
3.2
Temperature conditions
The Baseband module complies with the SPR4 Operating Conditions.
1) Operational temperature range (all specifications met within this range) –10°C...+55°C
(2) Functional temperature range (Reduced performance) -25°C... -10°C and +55°C...+70°C
(3) Storage temperature range: –40°C...+85°C
Humidity
Relative humidity range is 5...95%. The BB module is not protected against water. Condensed or splashed
water might cause malfunction. Any submerge of the phone will cause permanent damage. Long-term high
humidity, with condensation, will cause permanent damage because of corrosion.
ESD immunity
ESD limits are +-8kV for galvanic contact and +-15kV for air discharge.
Issue 1
Nom
Max
+5.4
+16V

Table 6 DC characteristics

Nom
Max
3.6
4.2
COMPANY CONFIDENTIAL
Copyright © 2007 Nokia. All rights reserved.
Unit
V
Battery voltage maximum value is
specified during charging is active
V
Unit
V
3.2V is cut off voltage
Notes
Notes
Page 1 –9