8.2.8

Trigger inputs/24 V DC out

Trigger voltage:
< 24 V
Type
Momentary or latching
Normally opened (default) or normally closed
Emergency input supervision:
10 kΩ + 10 kΩ series and parallel resistors
24 V DC out:
24 V(DC)
VOX switch:
Normally opened
8.2.9

VOX input

Type:
3-pin XLR, 6.3 mm jack socket, balanced
Sensitivity:
1 mV +1/-3 dB (mic), 1 V +1/-3 dB (line)
Impedance:
> 10 kΩ
VOX threshold:
100 µV (mic), 100 mV (line)

8.2.10 BGM

Type:
Cinch, stereo converted to mono
Nominal input level:
200 mV - 2 V

8.2.11 Line out

Type:
3-pin XLR, 6.3 mm jack socket, balanced
Nominal output level:
1 V
Maximum output level:
2 V

8.2.12 External booster

Type:
3-pin XLR and screw terminals
Controller output/External booster input voltage:
1 V
Controller input/External booster output voltage:
100 V
Bosch Security Systems | 2004-06 | 9922 141 ?????en

8.2.13 Environmental conditions

Operating temperature range:
-10 to +55 °C
Storage temperature range:
-40 to +70 °C
Relative humidity:
< 95%

8.2.14 General

EMC emission:
According to EN55103-1
EMC immunity:
According to EN55103-2
Dimensions:
19" wide, 3 U high
19" mounting brackets:
included
Weight:
approx. 20 kg