Plena Voice Alarm System | Installation and User Instructions | Glossary
F
Fault state
If a supervised function fails, the system automatically
enters the fault state. The integrated beeper starts,
the fault contact is activated and the corresponding
LED on the front of the controller is turned ON.
Fireman's control panel
The controller provides a CAN interface (9-pin D sub
connector) for the connection of a remote fireman's
control panel.
Firmware
The firmware of a controller and a router can be
upgraded with the latest version via the PC.
I
IEC60849
The Plena Voice Alarm System is compliant with the
international standard IEC60648, which describes
evacuation standards applicable to emergency
systems.
Firmware
The firmware of a controller and a router can be
upgraded with the latest version via the PC.
L
LED
Light Emitting Diode's are used on the frontside of the
controller/Router for indication purposes.
Line fault
A fault in a loudspeaker line (A or B) is indicated by
the corresponding LED on the frontside of the
controller/Router. All loudspeaker lines are
supervised.
M
Message manager
The message manager is integrated in the controller
and manages all prerecorded chimes and messages
as one central audio source.
Monitoring
A build-in loudspeaker on the front of the controller,
can be used to monitor the Plena Voice Alarm System.
Use the Monitor DIP switch on the rearside of the
controller, to enable the monitoring loudspeaker.
Bosch Security Systems | 2004-06 | 9922 141 10381en
P
PA system
Public Address system.
PC
A Personal Computer, running the Configuration
Software, is used to configure a Plena Voice Alarm
System. The PC is connected to the controller, via a
USB connection.
Phantom power
A DC voltage to supply a VOX microphone with, if
required. A DIP switch on the rearside of the
controller switches the phantom power ON or OFF.
Plena Voice Alarm System
IEC60648 compliant PA/EMG Voice Alarm System,
developed by Bosch Security Systems, suitable for
mid-range applications. The complete PA/EMG Voice
Alarm System comprising a controller, one or more
call stations, optionally one or more routers and other
optional Plena equipment, serving one or more
loudspeaker zones.
Praesideo
IEC60648 compliant PA/EMG Voice Alarm System,
developed by Bosch Security Systems, suitable for
mid-range applications.
Priority
Various input sources can be assigned a priority.
Higher priority input sources will overrule
simultaneously active lower priority input sources.
PTT
A PTT (Push To Talk) button (the big button on a call
station) can be used to activate a call station's
microphone in order to make a spoken message.
R
RJ45
RJ45 connectors are provided at the rearside of the
controller, for the connection of the call station(s) and
the router(s).
RCP
A Remote Control Panel can be connected to the
controller to provide similar functionality on a remote
location. RJ45 connectors are used to connect the
RCP and the controller, over an RS-485 CAN
interface. The BGM of the controller is digitally
transferred to the RCP.