Plena Voice Alarm System | Installation and User Instructions | System units
1
Plena Voice Alarm Controller
Fault Indicators
0 dB
Processor reset
Network
-6dB
Call/EMG
-20dB
Music/Spare
Ground short
Input
EMG mic
17
16
18
19 20
1 Channel
2 Channel
Int Booster
BGM/ C all
BGM/ Spare
Ext Booster
N.C ./Spare
Call
Override/Trigger Output
A
B
24V
100V
100V
Z1
Z1
Z1
0
0
Z2
100V
100V
Z2
Z2
0
0
Z3
100V
100V
Z4
Z3
Z3
0
0
Z5
100V
100V
Z4
Z4
0
0
Z6
100V
100V
Z5
Z5
TRG 1
0
0
100V
100V
Z6
Z6
0
0
Ext
100V
100V
Int
B ooster
In
B ooster
0
70 V
Out
0
DC In
24V
10 0V
C all out
46
45
44
43
figure 3. 1 1: Front and rear views of the voice alarm controller
22 Call station sockets - Two redundant RJ45
sockets to connect call stations (LBB1956/00) to the
voice alarm controller (see section 3.8).
23 Service settings - A set of DIP switches to service
the voice alarm controller. Do not change the
positions of the switches.
24 Calibration switch - A switch to calibrate the
impedances of the loudspeaker lines for loudspeaker
supervision (see section 4.5.5.3).
25 Configuration settings - A set of DIP switches to
configure the voice alarm controller (see section 4.2).
Bosch Security Systems | 2004-06 | 9922 141 10371en
2
3
Disabled
A
B
Fault
Mains
Zone1
Battery
Zone2
Message
Zone3
EMG mic
Zone4
Zone5
RCP
Router
Zone6
Alert message
All call
Alarm message
Indicator test
-
+
+
-
13
10
15
14
12
11
9
21
Trigger input/24V DC out
Emergency
1
2
3
4
5
Business
1
2
3
4
5
NC
NO
NC
COM
EM G
1
2
3
4
5
COM
NO
NC
COM
Fault
NO
NC
COM
C all
NO
NC
24V
Volume Override
NO
1
2
3
4
5
TRG2
In
Out
GND
External Booster
CD/Tuner
42
41
40
39
4
EMG
Ack
Zone select
Reset
Zone1
Zone2
Select
Zone select
CD/Tuner
Aux
0
8
7
22
23 24
24V
6
DC out
10 k
10 k
VO X
6
Switch
Call station
For ser vice only
24V
SEL1
Monitor
6
DC out
APR mode
SEL0
Supervision
Firmware
2ch operation
Upgrade
1
LBB1994
Off
2
On
Impedance
6
VOX Switch
Calibration
GND
L
Mic/Line
R
AUX
PC
Vox
38
37
26 PC socket - A USB socket to connect the voice
alarm controller to a PC. Not for use in basic
systems.
27 Fireman's panel port - An RS232 port to connect
a fireman's panel to the voice alarm controller. Not
for use in basic systems.
28 LBB1994 port - Reserved.
29 Voltage selector - A voltage selector to select the
local mains voltage (see section 3.15).
30 Power switch - A switch to switch the voice alarm
controller on and off (see section 5.1).
5
Zone3
Zone4
Zone5
6
25
26
27
28
LBB 1 990/00
8900 199 0 0001
Plena Voice Alarm Controller
Max. output power 360W
Rated output power 240W
115-230V~, 50/60Hz
S/N.
N6 63
Design & Quality
The Netherlands
Fireman's panel
USB
Off
LBB1994
On
Line fuse
T6.3L250V for230V AC
T10L250V for115V AC
Remote Control Panel
Vox
Speech filter
1
Phantom power
Router
Off
2
On
Digital
Monitoring
Mess age
Speaker
36
35
34
33
en | 26
Alarm
Zone6
29
30
115V~
230V~
Apparatus delivered
C onnected for 230V~
Power
Rated input power :760VA
W arning
This apparatus must be earthed