Fcm Replacement; Night Light™ Replacement - Napoleon XIR3N Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

28
8.6

FCM REPLACEMENT

EN
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
THE APPLIANCE MAY BE HOT. DO NOT SERVICE APPLIANCE UNTIL IT HAS COOLED.
A.
To access the fan control module, you must fi rst pull out
the appliance, allowing enough room to access the left
access plate.
B.
Remove the screws holding the access plate in position.
C.
Unplug the fan control module from the
junction box. Unplug the night light plug and
blower plug (if applicable) from the
fan control module.
D.
Remove the 2 screws securing the fan control to
the access plate and replace. NOTE: Ensure
that the ON/OFF switch is in the ON (-) position.
E.
Reinstall the plugs and access plate
8.7
NIGHT LIGHT™ REPLACEMENT
Your appliance comes equipped with our "Night Light™". The light has been pre-wired and is controlled from
the remote control.
If the lamp or lens needs to be replaced, follow the instructions below.
A.
Unplug the
the left access panel.
B.
Remove the four screws that secure the lens frame. This frame
retains the glass lens. The lamp can now be accessed.
NOTE: Do not handle the lamp (bulb) with bare fingers, protect with a
clean dry cloth.
The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as
lamp and lens are special "high temperature" products. When re-installing, ensure
integrity of gasket seal.
THE FIREBOX MUST BE SEALED.
Over-tightening the screws could break the lens. "Light Leakage" from the upper
area may be observed. The holes in the lamp housing are necessary for ventilation
and must not be covered.
W415-1343 / 10.07.14
fan control module
from the junction box located behind
WARNING
!
ON/OFF
SWITCH
ACCESS PLATE
GASKET
LENSE
FRAME