INSTALLATION CLEARANCES
These vent hoods are designed to be installed onto
a wall with no above cabinets.
• Install these hoods between the required 24"
minimum and 36" recommended maximum
above the cooking surface.
The vent hood must be installed between the
required 24" minimum and recommended 36"
maximum above the cooking surface. The hood
installation height above the cooking surface
depends upon ceiling height and duct cover
limitations. The telescopic duct cover conceals
the ductwork running from the top of the hood to
the ceiling.
NOTE: Installation height should be measured from
the cooking surface to the lowest part of the hood.
This hood must be installed onto a wall. It can be
vented to the outdoors, or it can be installed for
recirculating operation. Recirculating Kit included
with hood.