Pre-Inspection - MULTIQUIP J-36 Operation And Parts Manual

Whiteman series
Hide thumbs Also See for J-36:
Table of Contents

Advertisement

DANGER
DANGER
DANGER
DANGER
DANGER
EXPLOSIVE FUEL!
Motor fuels are highly flammable and can
be dangerous if mishandled. DO NOT
smoke while refueling. DO NOT attempt to
refuel the trowel if the engine is hot! or
running .
Fuel Check
1. Remove the gasoline cap located on top of fuel tank.
2. Visually inspect to see if fuel level is low. If fuel is low, replenish
with unleaded fuel.
3. When refueling, be sure to use a strainer for filtration. DO
NOT top-off fuel. Wipe up any spilled fuel.
Gearbox Oil
Determine if the gearbox oil is low by removing the oil
1.
plug located on the side of the gearbox. (Figure 21) This
plug will be marked by the " check " decal. The correct level
of the lubrication oil should be to the bottom of the fill plug.
1
1
Gear Box
2
Oil Sight/Fill Plug
3
Drain Plug
Figure 21. Gearbox
2.
If lubrication oil begins to seep out as the drain plug is
being removed, then it can be assumed that the gearbox
has a sufficient amount of oil.
3.
If lubrication oil does not seep out as the drain plug is
being removed, fill with type ISO 680 (Whiteman P/N 10139)
gearbox lubricant oil until the oil filler hole overflows.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
Disconnect the spark plug wire from the spark plug and
secure away from the engine before performing
maintenance or adjustments on the machine.
PAGE 24 — J-36/M-30 WALK-BEHIND TROWEL — OPERATION AND PARTS MANUAL — REV. #0 (12/29/06)
J-36/M-30 TROWEL— PRE-INSPECTION
2
3
V-Belt Check
A worn or damaged V-belt can adversely affect the performance
of the trowel. If a V-belt is defective or worn simply replace the V-
belt as outlined in the maintenance section of this manual.
Belt Guard Check
Check for damage, loose or missing hardware.
Blade Check
Check for worn or damaged blades. Check to see if one blade is
worn out while the others look new. If this is the case there could
be a blade pitch problem. Refer to the maintenance section of
this manual for blade pitch adjustment procedure. Replace any
worn blades.
CONTROLS
Safety-Stop "Kill" Switches
This trowel has been equipped with a safety "kill" switch. This
switch should be tested every time the engine is started.
WARNING
WARNING
WARNING
WARNING
WARNING
NEVER disable or disconnect the safety "kill" switch. It is
provided for operator safety. Injury may result if it is disabled,
disconnected or improperly maintained.
Centrifugal Type "Kill" Switch
(Figure 22) The switching mechanism of this switch should
operate freely and should always be kept in this condition. With
the switch in the OFF position, the engine should not start or run.
The purpose of this switch is to stop the engine in a runaway
situation, (i.e. the operator releasing the handle during operation).
3
2
1
"Kill" Switch (Safety Stop)
2
"ON" Position
3
"OFF" Position
Figure 22. Centrifugal "Kill" Switch
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

M-30

Table of Contents