Figure 1. Connectors and controls of the 5040A.
center of the front loudspeaker array.
Two phase matching switches in the
crossover allow compensation for incorrect
phase alignment. Four settings are provided
between 0° and -270°.
Coarse phase
correction method
Connect an audio frequency signal generator
to a signal input on the subwoofer which has
a main loudspeaker connected to the corre-
sponding "OUT" connector. Set the generator
to 85 Hz. If a signal generator is not available,
then it is possible to use an audio test record-
ing which has a test frequency in the range
70 Hz to 100 Hz. Suitable test signals can be
downloaded at www.genelec.com.
• Toggle the -180° phase
switch 'ON' and 'OFF' and
set it to the position which
gives the lowest sound level
at the listening position.
• Next toggle the -90°phase
switch 'ON' and 'OFF', and
again set it to the position
which gives the lowest
sound level.
• Finally, set the -180°phase
switch to the opposite
setting.
Automatic protection circuits
The 5040A is equipped with protection cir-
cuits against loudspeaker driver thermal
overload and amplifier overheating. The pro-
tection system resets automatically so that
the user only has to turn the input level down
to ensure that it does not reactivate.

Safety considerations

The Genelec 5040A complies with interna-
tional safety standards. However, to ensure
safe operation and maintain the equipment in
safe operating condition the following warn-
ings and cautions must be observed.
• Servicing and adjustment must only be
performed by qualified service personnel.
• Opening the amplifier panel is strictly
prohibited except by qualified service
personnel.
• Do not expose the subwoofer to water or
moisture. Do not place any objects filled
with liquid, such as vases on the
subwoofer or near it.
• Note that the amplifier is not completely
disconnected from the AC mains service
unless the mains cable is removed from
the amplifier or the mains outlet.
Warning!
This equipment is capable of delivering sound
pressure levels in excess of 85 dB, which
may cause permanent hearing damage.

Maintenance

There are no user serviceable parts inside
the subwoofer. Any maintenance of the unit
must only be performed by qualified service
personnel.
Guarantee
This product is supplied with two year guaran-
tee against manufacturing faults or defects that
might alter the performance of the unit. Refer
to supplier for full sales and guarantee terms.
EC Declaration of Conformity
This is to certify that the Genelec Active Subwoofer 5040A
conforms to the following standards:
Safety:
EN 60065: 2002 + A1:2006 /
IEC 60065:2001 7th Edition + A1: 2005
EMC:
EN 55020: (2002) + A1 : 2003
EN 55013: (2001)+ A1 : 2003
EN 61000-3-2 (2000)
EN 61000-3-3 (1995)
The product herewith complies with the requirements of
The Low Voltage Directive 2006/95/EC and EMC Directive
2004/108/EC
Signed:
Ilpo Martikainen
Position:
Chairman of the Board
Date:
26-May-2008