  • Page 2: Mounting Considerations

    A minimum clearance of 2.5 centimeters (1 in) Packing contents behind, above and on sides of the monitor must be Each 8010A is supplied with a mains cable and found. The space adjacent to the amplifier must ei- this operating manual.
  • Page 3: Mains Connector

    XLR SIGNAL MAINS INPUT MAINS 50 / 60 Hz 30 W 100 - 240 V~ INPUT CONNECTOR 8010A BI-AMPLIFIED MONITORING SYSTEM CONNECTOR MADE IN FINLAND www.genelec.com Figure 3. Control and connector layout on the rear panel of a 8010A. 2 English...
  • Page 4: Tone Controls

    Table 1: Suggested tone control settings for various acoustical environments Autostart function Tone controls The signal sensing Autostart function of the 8010A The frequency response of the Genelec 8010A powers it up when playback begins. Automatic can be adjusted to match the acoustic environ-...
  • Page 5: Mounting Options

    This equipment generates, uses and can radiate radio frequency energy and, if not unit. Any maintenance or repair of the 8010A should installed and used in accordance with the instructions, may cause harmful interfer- only be done by qualified service personnel.
  • Page 6 (dBr) vs freq (Hz) 10 Jan 13 Figure 5. The upper cur ve group shows 0° the horizontal directiv- ity characteristics of the 15° 8010A measured at 1 m. 30° The lower curve shows 45° the system's power re- 60° sponse.
  • Page 7: System Specifications

    sysTEM spECiFiCATions CrossovEr sECTion Lower cut-off frequency, –6 dB: < 67 Hz Input connector: XLR female 7 kOhm: pin 1 gnd, pin 2 + Upper cut-off frequency, –6 dB: > 25 kHz pin 3 - Free field frequency response (± 2.5 dB): 74 Hz–20 kHz Input level for 100 dB SPL output at 1 m: -6 dBu...
  • Page 8 Jianwai SOHO, Building 12, Room 2605 D-1504, Chaoyang District Beijing 100022, China Phone +86 10 8580 2180 Fax +86 10 8580 2181 Email genelec.china@genelec.com www.genelec.com Genelec Document D0117R001 Copyright Genelec Oy 1.2014. All data subject to change without prior notice.
  • Page 9 8020C Data Sheet...
  • Page 10 System made via a balanced female XLR connector. cuit that monitors the output levels and pre- The Genelec 8020C is a very compact bi- The volume control is located on the front vents any damage to the drivers. This makes amplified active monitor system with perfor- panel.
  • Page 11 The Minimum Diffraction Enclosure™ the available system maximum sound pres- (MDE™) Technology increases the perfor- sure level. mance of the Genelec 8000 Series loud- Mounting Figure 3: The curved reflex tube provides low speakers by minimizing edge diffraction and distortion and excellent bass extension.
  • Page 12: Data Sheet

    Fax +358 17 812 267 Email genelec.usa@genelec.com Fax +46 8 708 7071 Phone +86 10 8580 2180 Email genelec@genelec.com Email info@genelec.com Fax +86 10 8580 2181 Email genelec.china@genelec.com Genelec Document BBA0088001a Copyright Genelec Oy 9.2013. All data subject to change without prior notice www.genelec.com...
  • Page 13 8030B Data Sheet Genelec 8030B Active Monitoring System...
  • Page 14 The ampli- male XLR output connector can be used fier unit also contains a protection circuit that The Genelec 8030B is a very compact bi- for connecting a 7050A subwoofer or daisy monitors the output levels and prevents any amplified active monitor system with perfor- chaining up to six 8030B’s together.
  • Page 15 The Minimum Diffraction Enclosure™ maximum sound pressure level. (MDE™) Technology increases the perfor- Mounting mance of the Genelec 8000 Series loud- Figure 3: The curved reflex tube provides low speakers by minimizing edge diffraction and The 8030B offers several mounting options: distortion and excellent bass extention.
  • Page 16 Genelec Document BBA0036001a Copyright Genelec Oy 9.2013. All data subject to change without prior notice International enquiries: In Sweden please contact In the U.S. please contact:...
  • Page 17 8040B Data Sheet Genelec 8040B Active Monitoring System...
  • Page 18 The Genelec 8040B is a compact bi-amplified The integrated design allows the amplifiers jective sound quality currently possible. The active monitor system with performance com-...
  • Page 19 Figure 3: The curved reflex tube provides low (MDE™) Technology increases the perfor- The 8040B offers several mounting options: distortion and excellent bass extention. mance of the Genelec 8000 Series loud- The vibration insulating Isolation Positioner/ speakers by minimizing edge diffraction and Decoupler™ (Iso-Pod™) table stand allows improving frequency and power response.
  • Page 20 8040B Data Sheet Genelec Oy 8040 (dBr) vs freq (Hz) 6 Apr 04 Genelec Oy 8040 horizontal off axis response level (dBr) vs freq (Hz) 6 Apr 04 0° 15° 30° DESKTOP LF 45° BASS TILT 60° BASS ROLL-OFF TREBLE TILT Figure 3: The upper curve group shows the horizontal directivity char- Figure 4: The curves above show the effect of the “bass tilt”, “treble...
  • Page 21 5040A Operating Manual Genelec 5040A Active Subwoofer...
  • Page 22: General Description

    The Genelec 5040A is a very compact active directs the frequencies below 85 Hz to the If the frequency balance is not quite right,...
  • Page 23: Safety Considerations

    This is to certify that the Genelec Active Subwoofer 5040A ing which has a test frequency in the range conforms to the following standards: 70 Hz to 100 Hz.
  • Page 24 Phase matching control in 90° steps From 0 to -270° @ 85 Hz www.genelec.com Genelec Document D0078R001. Copyright Genelec Oy 6.2008. All data subject to change without prior notice International enquiries: In Sweden please contact In the U.S. please contact:...
  • Page 25 7040A Operating Manual Genelec 7040A Active Subwoofer...
  • Page 26: Bass Management

    0° and -270°. Genelec! Driver Amplifier Since 1978, Genelec has been guided by a single idea – to make perfect active moni- The 7040A contains one 165 mm (6.5 A Class D power amplifier produces 50 tors that deliver neutral and accurate sound...
  • Page 27 MADE IN FINLAND BASS ROLL-OFF PHASE AND 7040A ACTIVE SUBWOOFER SERIAL SIGNAL INPUT NUMBER MAGNETICALLY SHIELDED ISS DISABLE SWITCHES CONNECTORS -4 dB ROLL-OFF -2 dB -270° -90° -180° ISS-DISABLE POWER LEFT IN RIGHT IN SENSITIVITY SIGNAL OUTPUT FOR 100 dB...
  • Page 28: Operating Environment

    Subwoofer placement Bass Roll-Off setting Near to a wall -2 dB In a corner -6 dB Flush mounted -2 dB Phase Difference: 90° Phase Difference: 0° Table 1. Suggested Bass Roll-Off settings 85 Hz 85 Hz Phase Difference: 270° Phase Difference: 180° 85 Hz 85 Hz Figure 5.
  • Page 29 85 Hz are reproduced amplifier unit. Any maintenance of the at equal level. Then, adjust the phase unit must only be performed by Genelec switches for the maximum dip of at least authorized service personnel. -6 dB at the crossover frequency (85 Hz).
  • Page 30 0 dB Input sensitivity control +12 to -6 dBu www.genelec.com Genelec Document D0126R001 Copyright Genelec Oy 3.2015. All data subject to change without prior notice International enquiries: In Sweden please contact In the U.S. please contact: In China please contact:...
  • Page 31 7050B Data Sheet Genelec 7050B Active Subwoofer...
  • Page 32 L/R Rear) and a LFE input, providing great load and short circuit protection. some larger Genelec models - one of the dif- flexibility and easy connection. The discrete ferences is the greater SPL’s offered by larger...
  • Page 33 Figure 2: 7050B harmonic distortion analysis in free field. In half space the SPL will be 6 Figure 1: The amplifier panel layout of a 7050B subwoofer. dB higher. desks and, if carefully placed appear fairly sequencers and multimedia sources, such as innocuous in a room.
  • Page 34 Input connectors. LFE input sensitivity control 0 or +10 dB selectable www.genelec.com Genelec Document BBA0061001. Copyright Genelec Oy 5.2007. All data subject to change without prior notice In Sweden please contact International enquiries: In the U.S. please contact In China please contact: Genelec, Inc., 7 Tech Circle...
  • Page 35 LSE Series Data Sheet Genelec 7060B, 7070A and 7071A Active Subwoofers...
  • Page 36 LSE series subwoofers may be used with pass section has an adjustable sensitivity, great flexibility and easy connection. The other Genelec monitors to extend their low to allow easy level matching with the main discrete LFE signal input is equipped with a frequency response and SPL performance.
  • Page 37 Figure 1: The amplifier panel layout of a 7000 series subwoofer. using the "redirect" function. In this case, frequencies above 85 Hz in the LFE signal are redirected to the center channel output to be reproduced by the center channel moni- tor.
  • Page 38 0/-2 dB/ -4 dB/ -6 dB @ 20 Hz Phase 0/90/180/270° www.genelec.com Genelec Document BBA0032001c. Copyright Genelec Oy 3.2006. All data subject to change without prior notice In Sweden please contact International enquiries: In the U.S. please contact In China please contact:...

Table of Contents