GAS INStALLAtION INFORMAtION
UNDERBENCH OvENS
Your underbench oven looks best when the control panel
is directly under the benchtop . An upper infill panel
may have to be added if the cooktop placed above the
benchtop is too deep .
Refer to cooktop installation instructions for required
clearance between cooktop and oven .
D: Gas connection – 150mm from right hand side
– 220mm from bottom
E: Electrical connection – 50mm from right hand side
INSTALLATION
26
upper infill if required
D
1.7m flexible gas hose
(supplied unfitted)
E
1.5m electrical
service cord
– at bottom
A
B
558
C
Use long black
installation screws
596
supplied
GAS tYpE
Flush fit
Proud fit
carry handle
553
*20
15
595
mounting
holes
A
B
600
600
565
590
8mm min
clearance
C
581min
560min