(9)
Attach the developer material cover and
tighten 2 screws.
Notes:
1. After the developer material has been
replaced, adjust the auto-toner sensor.
(See
P.3-2 "3.2 Adjustment of Auto-
Toner Sensor".)
2. When installing the developer unit upper
cover, make sure that the side seal
comes between the developer unit upper
cover and rubber seal on the cover.
e-STUDIO205L/255/305/355/455
ADJUSTMENT
Rubber seal
Developer unit
upper cover
© 2009 TOSHIBA TEC CORPORATION All rights reserved
3 - 60
Developer
material cover
Fig. 3-54
Side seal
Fig. 3-55