Toshiba e-STUDIO205L Service Handbook page 261

Hide thumbs Also See for e-STUDIO205L:
Table of Contents

Advertisement

[H] Bottom margin
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Open the original cover or RADF.
(3)
Press the [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and the lower drawer
(Refer to *).
(4)
Measure the blank area G at the trailing edge of the copied image.
(5)
Check if the blank area G is within the range of 2±1.0 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
(Key in value (acceptable values: 0 to 255))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
("100% A" is displayed.)
* The larger the adjustment value is, the wider the blank area at the trailing edge becomes
(approx. 0.04 mm/step).
© 2009 TOSHIBA TEC CORPORATION All rights reserved
(Key in the code [433])
Feeding direction
G
Fig. 3-19
3 - 21