Mains Power Supply In Conjunction With On-Site Power Consumption; Closing The Heat Pump - Viessmann VITOCAL 200-S Installation And Service Instructions Manual

Table of Contents

Advertisement

Installation sequence
Power supply
(cont.)

Mains power supply in conjunction with on-site power consumption

Without power-OFF
A
F
G
kWh
L
M
N
Fig. 29
Heat pump
A
Additional consumers (of power generated on site)
B
in the household
Electricity meter
C
Inverter
D
Isolator for the PV system
E
F
Terminal
Double-tariff meter (for special tariff for heat pump)
G
Not permissible in conjunction with PV systems for
on-site power consumption

Closing the heat pump

!
Please note
Seal the appliance so it is soundproof and diffu-
sion-proof.
On pipe and hose outlets, ensure the thermal
insulation is seated correctly.
38
B
A
C
F
N
E1E2
D /D
F
L1 L1 L2 L2 L3 L3
H
kWh
L
N
~ ~
=
D
E
F
K
kWh
M
Bi-directional meter (for PV systems to consume
H
power on site):
Energy taken from power supply utility and energy
fed into power supply utility
Meter with reverse block:
K
For energy generated by PV system
Isolator for the domestic power supply connection
L
(distribution panel)
Distribution panel
M
Domestic distribution box
N
Danger
The absence of component earthing can lead to
serious injury from electric current if an electrical
fault occurs.
Attach earth conductor to front panel and side
panel.