D. Blower Replacement
1. The grille on the blower access assembly is hinged. Swing
the grille downward to expose the 2 screws. Figure 23.1.
2. Remove the 2 screws from the blower access assembly
and slide assembly away from the appliance.
3. Disconnect the wires from the blower.
4. Remove the 2 screws from the hold down bracket and pull
the blower and bracket forward.
5. Remove the blower from the hold down bracket.
6. Remove the protection guards from each end of the blower.
7. Re-install in reverse order. Be certain that the hold down
bracket's screws are completely seated in the grommets.
Insert the locating tab in the hold down bracket into the
placement slot.
Blower Access
Grille hinges
downward
Remove Screws &
Pull Access Assembly
away from Insert
Figure 23.1
July 8, 2015
Assembly
Hold Down
Bracket
Shock Risk.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
Placement Slot
Remove Screws from Hold
Down Bracket and Pull
Forward