Installation
The room thermostat must be connected to
the terminal block situated next to the control
panel.
When connecting any type of external
control, the jumper K in Fig. 5.8 must be
removed.
7.
Connect the room thermostat between
terminals 1 and 3 as shown in Fig. 5.9.
Do not connect live wires to terminals to
which the room thermostat must be
connected.
The insulating class of the room thermostat
must be II (
) or the thermostat must be
correctly earthed.
8.
Route the electrical supply flexible cord
and the external control flexible cord as
illustrated in Fig. 5.10. Lock the flexible
cords in place with the flexible cord
clamps
Комнатный
термостат
Room
thermostat
L
T
3
2
1
30
Power supply
terminal block
N
Клеммная
колодка
электропитания
External controls
terminal block
Клеммная
колодка для
устройства
внешнего
контроля
Fig. 5.9
Комнатный
термостат
подключен через клеммную колодку для
устройства внешнего контроля.
В случае подключения устройств внешнего
контроля перемычка К на рис 5.8 должна
быть демонтирована.
7.
Подключите
между контактами 1 и 3 как показано
на рисунке 5.9
Не подключайте фазу к контактам, к
которым будет подключен комнатный
термостат.
Комнатный термостат должен иметь 2
класс по электроизоляции и правильно
заземлен.
8.
Разведите провод электропитания и
провод
внешнего
указано на рис. 5.10. Зафиксируйте
гибкий провод при помощи хомутов.
To the external
control device
устройству
К
внешнего
контроля
Fig. 5.10
должен
быть
комнатный
термостат
контроля,
To the fused
spur isolation
switch
К автомату
электропитания
как

Advertisement