CHAPTER 5 SERVICE MODE
ACC
Use it to make accessories-related settings.
COIN
Use it to turn on/off the coin vendor indication.
• The control card indicator used on the control panel may be used for the
Settings
0: OFF (default), 1: ON (for count vendor)
DK-P
Use it to set a paper of the paper deck.
Caution
After electing the appropriate paper size, be sure to turn off and then on the
main power switch.
Settings
0: A4 (default), 1: B5, 2: LTR
TEMPO
Use it as an emergency remedy when the potential sensor or the environment sensor is
faulty (out of order).
F-POT-SW
Use it to turn on and off the setting if a transfer fault occurs because of a
fault (error) in the potential sensor.
• Use it as an emergency remedy until the potential sensor is replaced.
Settings
0: OFF (default), 1: enables F-POT-D setting
F-POT-D
Use it if a transfer fault occurs because of a fault (error) in he potential sen-
sor.
• It is valid only when F-POT-SW is set to '1'.
• The level of separation current is in the order of 0>1>2.
Settings
0: for text-oriented users (originals with low image ratio)
1: for photo-oriented users (originals with high image ratio)
2: not used usually; however, if re-transfer (white spot at 50 mm
along leading edge) occurs
F-HUM-SW
Use it to turn on and off F-HUM-D if the environment senor has a fault (er-
ror).
• Use it as an emergency remedy until the environment sensor is replaced.
Settings
0: OFF (default), 1: enables F-HUM-D
5-90 T
coin vendor.