Reset; Precautions; Specifi Cations - Oregon Scientific RMR683HG User Manual

Digital thermometer with humidity, ice alert and radio-controlled clock
Hide thumbs Also See for RMR683HG:
Table of Contents

Advertisement

RESET

Press RESET to return the unit to the default settings.

PRECAUTIONS

This product is engineered to give you years of
satisfactory service if you handle it carefully. Here are
a few precautions:
Do not subject the unit to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit's internal components.
Doing so will invalidate the warranty on the unit and
may cause unnecessary damage. The unit contains
no user-serviceable parts.
Only use fresh batteries as specifi ed in the user's
instructions. Do not mix new and old batteries.
Due to printing limitations, the displays shown in this
manual may differ from the actual display.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose this product as unsorted municipal
waste. Collection of such waste separately for
special treatment is necessary.
RMR683HG_M_EN_RC3.indd 11
NOTE The technical specifi cations for this product and
The technical specifi cations for this product and
the contents of the user manual are subject to change
without notice.
SPECIFICATIONS
TYPE
TYPE
DESCRIPTION
DESCRIPTION
MAIN UNIT
L x W x H
L x W x H
97 x 127 x 70 mm
97 x 127 x 70 mm
( (3.94 x 5.20 x 2.87 in)
Weight
Weight
241 g (8.5 oz) without battery
241 g (8.5 oz) without battery
Temperature unit
Temperature unit
°C / °F
°C / °F
Temperature range
Temperature range
-5°C to 50°C (23°F to 122°F)
-5°C to 50°C (23°F to 122°F)
Resolution
Resolution
0.1°C (0.2°F)
0.1°C (0.2°F)
Clock frequency
Clock frequency
DCF-77 (EU) / MSF-60 (UK)
DCF-77 (EU) / MSF-60 (UK)
Synchronization
Synchronization
Auto or disabled
Auto or disabled
Signal frequency
Signal frequency
433 MHz
433 MHz
Clock
Clock
Auto or manual (disabled)
Auto or manual (disabled)
Humidity range
Humidity range
25% - 95%
25% - 95%
Humidity resolution
Humidity resolution
1%
1%
MEM
MEM
Min / Max relative humidity and
Min / Max relative humidity and
temperature
temperature
Alarm duration
Alarm duration
2 minutes
2 minutes
Snooze
Snooze
8 minutes
8 minutes
Clock display
Clock display
HH:MM:SS
HH:MM:SS
HH:MM:Day of Week
HH:MM:Day of Week
Hour format
Hour format
12 / 24 hour format
12 / 24 hour format
11
2006.5.26 11:11:20 AM

Advertisement

Table of Contents
loading