Service Diagnostics and procedures–Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.

Water valve

To access overload relay:
1. Slide unit out for service. Remove securing
screws and lower rear cover (see Overload
Relay section, Step 1, page 52).
2. Remove water valve retaining screw and slide
dual tube sweep out of back cover.
Dual Tube Sweep
3. Disconnect water lines.
© 2012 Viking Preferred Service
WARNING
4. Disconnect water valve electrical connections.
3. Repair or replace water valve.
Screw
4. Reverse procedure to reinstall.
Connector
53