Service Diagnostics and procedures–Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.
Refrigerator light Switch
To access the refrigerator light switches:
1. Open door and locate the light switch.
2. Use a flat blade to depress light switch securing
tabs.
Screwdriver
Blade
3. Pull switch into refrigerator compartment and
disconnect wiring.
4. Repair or replace switch.
5. Reverse procedure to reinstall.
© 2012 Viking Preferred Service
Light Switch
WARNING
Water Tank
To access the water tank:
1. Open door and remove shelves and drawers.
2. Remove 1/4" screws securing water tank.
Screw
3. Disconnect tank and water lines.
4. Remove water tank.
5. Reverse procedure to reinstall.
Water Line
33