2.
Set Hodel ZC-80 unit in place and attach safety shield to
unit as shown in Figure i-A and i-B. You must place a noncom-
bustible material 3/4" thick millboard or equivalent K Factor
=.084/BTU/F 2 H0F inches minimum.
3. Frame the ZC Cabinet usng 2"x 4" studs or local building code
framing.
Some minor framing restrictions are required:
A.
Adjacent side walls must be at least 6" from the outer edge
of the Cabinet trim panel.
B.
The overall opening dimensions must be at least 47 1/2" Hide
and 41 1/2" high.
C.
Framing must protrude 2 1/2" to allow for finished wall to
come flush with the back of the ZC Cabinet trim panel (See Fig-
ures i-A and i-B).