7.10. Flow meter
Loosen the screws as illustrated and remove the gear motor assembly.
A
B
E
C
B
Saeco International Group
Services Unlimited, Inc./ Parts Guru
Remove the boiler support lift the fl ow
meter upwards and disconnect the electrical
and water circuit connections.
The following are located inside the compartment protected by
the casing:
- Electric motor (A) with gears (B) and (C) for transmission and
timing of the brewing unit.
- Microswitch (F) detecting brewing unit home and work posi-
D
tions.
- Remove the large gear (B)
- Remove the gear (C) that meshes with the motor transmission
shaft
- Remove the motor (A), complete with transmission shaft (E)
When re-assembling the
gear (B), make sure that
the arrow on the gear is
in the same position as
shown in the photo.
Loosen the screws as illustrated and remove
the gear motor cover.
When replacing the motor and the
transmission shaft, make sure the
guide runners (L) are in the right
position. Grease the shaft thoroughly
and evenly.
Rev. 01
07 DISASSEMBLY
L
Page
/ 09