Il. CHECKING
THE REGULATED
TENSION
OF THE REGULATORS
CHARACTERISTICS
- Two-stage
voltage
regulator
:
Ref : DUCELLIER
8379 A, PARIS-RHONE
AYC 2114 and AYC 2117.
SEV-MARCHAL
F. 14 V 72717102
These
voltage
regulators
determine
the intensity
of the current
in the alternator
inductor
in order
to maintain
a
constant
regulated
voltage
at the battery
terminals.
,
CHECKING THE REGULATED VOLTAGE
(.'hcckitlg
ti7c rc~~~~~l~tc~cl
u~IIcl,~c~
mris t 170 rnrric,rl
out
u,ith
a lrilly
darg~~rl
hnttcry.
Connect
up as per diagram
below,
using
a voltmeter
V, an ammeter
A and
a rheostat,
or better
still,
using
a
combined
o voltmeter/ammeter/
rheostat
)).
Start engine,
and let it idle.
Switch
off the ignition,
and immediately
switch
it back on in
order
to
demagnetize
the voltage
regulator.
Accelerate
the engine
so as to reach
the adjustment
speed
for the alternator.
Actuate
the rheostat,
smoothly
without
turning
it back,
in order
to increase
the current
supplied
by the alternator,
and read
the corresponding
voltage.
Take
several
measurements
of regulated
tension,
and check
that the values
obtained
are between
13 and 14.2 volts,
taking
into account
the correction
value
due to the temperature.
If the readings
are not correct,
replace
voltage
regulator.
Exe
Voltage
regulators
: DUCELLIER
8379
A
PARIS-RHONE
;;E
;;;;
-
SEV-MARCHAL
F.14 V72717102
- Adjustment
speed
: 6000 rpm (alternator)
2750 rpm (engine)
- R egulated
voltage
adjustment
:
between
13 and 14.2 V

Hide quick links: