6. Electric
cooling
fans
:
- 16 dm2 (248
sq.in ) radiator
( CX 2000 except
optional
towing
equipment
) ,.........
1
- 20 dm2 (310
sq.in ) radiator
(CX 2000 and 2200 except
optional
towing
equipment,
or torque
converter,
or air-conditioning)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
- 20 dm2 (310
sq.in ) radiator
( CX 2200 with
optional
towing
equipment
or
torque
converter
)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
20 dm2 (310
sq.in ) radiator
( CX 2200 with
air-conditioning)
,...............................
2
- 20 dm2 (310
sq.in)
radiator
( CX Prestige)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- 20 dm2 (310
sq.in)
radiator
(CX
2400, except
optional
towing
equipment
or torque
converter,
or air-conditioning
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
20 dm2 ( 310 sq .in ) radiator
( CX 2400 with
optional
towing
equipment,
or
torque
converter,
or air-conditioning
)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- 23 dm2 (356.5
sq.in ) radiator,
( CX 2400 GTi except
optional
towing
equipment
) 1
- 23 dm2 (356.5
sq.in)
radiator,
(CX
2400 and Prestige
with
optional
torque
converter
and air~conditioning,
and CX 2400 Gti with
optional
towing
equipment
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1 O-blade
fan
5-blade
fan
5-blade
fans
lo-blade
fans
1 O-blade
fans
1 O-blade
fan
1 O-blade
fans
10 blade
fan
lo-blade
fans
The electric
cooling
fans are controlled
by a thermal
switch
(011 /he
radiator)
e Power
rating
of electric
fan : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 W
Direction
of rotation
( S(J('IJ ~YOIII
c>lcctric
~/o/or side of
/alI
) :
.
. . . . Clockwise
- Cut-in
thermal
switch
:
1.6 dm2 (248
sq.in )
20 dm2 ( 310 sq.in ) and
radiator
23 dm2 (356.5
sq.in,)
rads
- Electric
fan ( s ) cuts in at
.
.
101
to
103.5"
c,
95 to loo0
c
-. Electric
fan ( s ) cuts out
(with
trmperatnw
decreasing
)
at : ._._._._._...........
9 5
to
920 c
95 to 9o"
c
- Tightening
torque
(fit gasket
with
LOCTITE
FRENETANCH
) : 1.8
to 2 da Nm
( 13 to 14.5
ft.lbs)

Hide quick links: