Operation; Installation - CITROEN CX 2000 Repair Manual

Table of Contents

Advertisement

OPERATION
No MA. 173-O : Chrrkivp
fhr prmd
s,,pp/>
Op. MA. 173.0
1
PETROL
PUMP
AC DELCO pump reference
E/PE
4.777
Auto-regulating
diaphragm lift and force pump
operated by eccentric
on camshaft.
This pump is fitted with (I device which enables it
to function on re-cycled
petrol. This re-cycling
is
effected
by means of a by-pass .( 1 ) fitted on the
carburettor
cover.
Excess
petrol supplied by the pump returns
to the
tank across an orifice
calibrated
from 0.8 to 0.9mm
in the by-pass
union (1).
PETROL
PUMP OUTPUT
(I) Otitput nil, maximum pressure
: 325 mbars (4 7 psi).
b) Output through open carburettor
float needle
valve.
500
45
88
3000
65
170
5500
69.5
192
I
I
Minimum pressure
in mbors
INSTALLATION
OF PETROL
PUMP
Fitted on the crankcase
with :
one (( Phenoploste
P12 )) spacer
5 + 0.1 mm thick.
two (< SOCOID a> paper gaskets
fitted dry.
Tightening
torque for petrol pump nuts :
21 mN ( 2.1 m.kg ).( 15 l/4
ft.lb )
CHECKING
THE STROKE OF THE PUMP PUSH-ROD
a) With the pump removed and using (I depth gouge A,
take the measurement
between the upper face of
the spacer ( with paper joints
) and the camshaft
eccentric
in its high
position
and in its low
position.
This measurement
should be :
- Upper position
of eccentric
27.4 ? 0.35 mm
- Lower position
of eccentric
32.4 rk 0.35 mm
b) Measure the length u a a) between the spring stop cup
and the tip of the pump control push-rod.
This length should be :
a = 4.5 mm minimum