CITROEN CX 2000 Repair Manual page 158

Table of Contents

Advertisement

OPERATION
No MA.
210-O
: (.h(~~-ki/lg
n~lc/ c~tlj~~s/irtg
the
igrlitiorl
Op.
MA.
210-O
3
1. Checking
the
condition
of the
contacts
:
Check the voltage
drop across
the contacts
( contacts
closed
) under a voltage
of 12 volts.
using
a test-bench.
The voltage
drop should
be 0.2 volts max.
I
2. Checking
the
centrifugal
advance
curve
:
a) Note the advance
in stages
for steadily
increasing
engine
speeds
from 0 to 3000 rpm. and for steadily
decreasing
engine
speeds
from 3000 rpm to 0, t~/~kjj/$ SII~L'
the
irirwasc,
or d~,rrc~as~'
is c-o~~ti~ootl.5.
These
points
must fall within
the shaded
area of the curve.
b) To a certain
extent.
it is possible
to correct
the advance
curve,
by altering
the tension
of the springs
for
the centrifugal
weights
To obtain
this condition,
slightly
bend (
iv
t/1(, np1)ro/)riotc,
ciirectioll
J the securing
brackets
for the springs,
or replace
them.
IY
NOTE
: If luminous
spots are produced
outside
the four normal
positions
at speeds
under
3000 rpm. make
5
sure the contact
points
are clean
and if necessary
make sure the test-bench
battery
is fully
charged.
before
U
replacing
the contact-breaker
unit.
the spring
of which
may have weakened.
7 co
m
r
3. Checking
the
spark
regularity
:
2
Whatever
the speed
of rotation,
the
angular
difference
of the four opening
positions
of the points
must
n.ot
3
exceed
lo
I 21n.xint~lm
r/In/
oj distributor
: 3250
I./)NI.
c,.vcc,pt
I)l'(.lit,t.tt~K
525 06X
A : 2750
r/m 1,
c
E
!i
a
z
4. Ch
k'
ec
rng
and
adjusting
the
dwell
angle
:
Run the distributor
at a steady
speed,
and check that the dwell
angle
is equal
;o 55' ? 2"30'.
If this is not the
case, adjust
the contact
breaker
to obtain
this condition.
5. Checking
the
ignition
condenser
:
With the contact
points
open. measure
the capacity
of the condenser;
This
value must be
0.30
i 0.03
wF.
If this is not the case. replace
the condenser.
6. Check
the
vacuum
advance
curve
:
This
check
is carried
out at a constant
rpm of 200,
with
no centrifugal
advance.
Check
the points
of the increasing
curve.
and the decreasing
curve.
If the vacuum
capsule
has n
hathcr.
it will
be necessary
to blank
it off during
this check.