Voltage And Resistance Checks (Self Clean Timer) - Viking VDSC305 Service Manual

30-36-48 inch
Hide thumbs Also See for VDSC305:
Table of Contents

Advertisement

MEASURED WITH DOOR OPEN
T4
107VAC
70VAC
T3
4VAC
16VAC
T2
4VAC
16VAC
T1
5VAC
MEASURED WITH DOOR LOCKED
T4
80VAC
56VAC
T3
85VAC
56VAC
T2
90VAC
T1
93VAC
VC--4VDC
SENSOR 3--3VDC SW2 closed in self clean
(Locked).
SENSOR 4--4VDC SW1 closed with clean
lock open.
M1--120VAC lock motor supply voltage.
(31VAC in locked position)
LS2--70VAC (unlocked)--55VAC (locked)
L1-- 70VAC (unlocked)--56VAC (locked)
L2/M2--16VAC (unlocked)--32VAC
(locked)
LS1--107VAC (locked or unlocked)
SEL--120VAC SUPPLY
VOLTAGE READINGS
1VAC
56VAC
56VAC
8

Hide quick links: