OPERATION
Voltage Selector Switch
The power available to each receptacle depends on the position of the
voltage selector switch.
Switch
Receptacle
Position
120V ONLY
120V/240V
120V ONLY Position
When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles. You must, however,
make sure the load on any receptacle does not exceed its available
power shown in the table above and the total load does not exceed
the total current available.
Total Current Available:
30.0 A (EM4000SX)
37.5 A (EM5000SX)
45.8 A (EM6500SX)
36
EM4000SX
30A at 120V
①
20A at 120V
②
20A at 120V
③
20A at 120V
None
15.0A at 120V
①
15.0A at 120V
②
15.0A at 120V
③
15.0A at 240V
-
Available Power
EM5000SX
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
18.8A at 120V
18.8A at 120V
18.8A at 120V
18.8A at 240V
EM6500SX
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
22.9A at 120V
20A at 120V
20A at 120V
22.9A at 240V