Honda EM4000SX Owner's Manual page 62

Hide thumbs Also See for EM4000SX:
Table of Contents

Advertisement

SERVICING YOUR GENERATOR
Battery Charging
The battery is rated at 11.2 Ah (ampere-hours). Charging current
should equal 10% of the battery's ampere-hour rating. A battery
charger should be used that can be adjusted to deliver 1.1 amps.
1. Connect the battery charger following the manufacturer's
instructions.
2. Charge the battery 5–10 hours.
3. Clean the outside of the battery and the battery tray compartment
with a solution of baking soda and water.
60
The battery will expel explosive
hydrogen gas when overcharged.
A spark or flame can cause the
battery to explode with enough
force to kill or seriously hurt you.
Always use a regulated charger that
provides the correct charging
current to prevent overcharging.
Wear protective clothing and a face
shield, or have a skilled mechanic
perform the battery maintenance.

Hide quick links: