8.
Click Next , bring up Fig. 39.
- Click Finish to exit the Step window.
- Serial number can be filled up at this moment (for example,
26MF605002).
NOTE: You must modify the Serial NO. In step 9, otherwise the Serial
NO. In OSD Couldn't be modified correctly.
Fig. 39
Step 5: Write DDC data
1. Configuration should be as Fig. 40. And press OK.
2. Access Factory Mode
1). Turn off monitor.
2). Press power "Power " button.Then quickly push " Volume -"
and " Volume ",and hold this two buttons,then the screen
comes out "Waiting For Automatic Adjustment ",then the screen
will be black for one second ,untill comes out "Windows screen"]
=> then release this two buttons, then press "Menu" button, wait
until the OSD menu with Characters "F1/FL1 NAFTA V0.91.1
041124ADJUST" (below OSD menu) come on the Screen of the
monitor (see Fig. 41).
Fig. 41
3) Push Menu to exit OSD menu.
"
"
3. Click
(Write EDID) icon from the tool bar to write DDC data.
Then wait for 20-30 seconds ,DDC data will be finished Writing.
Step 6: Save DDC data
Sometimes, you may need to save DDC data as a text file for using
in other IC chip. To save DDC data, follow the steps below:
1. Click
(Save) icon (or click "file"-> "save as") from the tool bar and
give a file name as shown in Fig. 42.
The file type is EDID46 file (*.ddc) which can be open in WordPad. By
using WordPad, the texts of DDC data & table (128 bytes, hex
code) can be modified. If DDC TEXTS & HEX Table ar completely
correct, it can be saved as *.ddc flie to re-load it into DDC IC for DDC
Data application.
DDC Instructions & Serial NO Definition
Fig. 40
Factory Mode
Indicator
Fig.42
2.
Click Save.
Step 7: Exit DDC program
Pull down the File menu and select Exit as shown in Fig. 43.
Fig. 43
Step 8: Turn off the monitor, exit the factory mode.
Serial Number Definition
BZ1A0525000001
Serial number (6 digits)
Production year/week code
Service version change code
BOM (bill of Material) code
Sit code (Production center) according
TY CODE ( TY---CHUNGLI, HD--
HUNGARY,BZ--SUZHOU, DS--DONG
GUAN)
BOM Code:
PANEL SUPPLIER
CODE
AU
1
CPT
2
LPL(LG)
3
QDI
4
26MF605W/17