In the field provided, type Ping followed by the IP address of the firewall, as in this example:
2.
ping 192.168.0.1
Click on OK.
3.
You should see a message like this one:
Pinging <IP address> with 32 bytes of data
If the path is working, you see this message:
Reply from < IP address >: bytes=32 time=NN ms TTL=xxx
If the path is not working, you see this message:
Request timed out
If the path is not functioning correctly, you could have one of the following problems:
Wrong physical connections
— Make sure the LAN port LED is on. If the LED is off, follow the instructions in
"Local or Internet Port Link LEDs Not
— Check that the corresponding Link LEDs are on for your network interface card and
for the hub ports (if any) that are connected to your workstation and firewall.
Wrong network configuration
— Verify that the Ethernet card driver software and TCP/IP software are both installed
and configured on your PC or workstation.
— Verify that the IP address for your firewall and your workstation are correct and that
the addresses are on the same subnet.

Testing the Path from Your PC to a Remote Device

After verifying that the LAN path works correctly, test the path from your PC to a remote device.
From the Windows run menu, type:
PING -n 10 <IP address>
where <IP address> is the IP address of a remote device such as your ISP's DNS server.
If the path is functioning correctly, replies as in the previous section are displayed. If you do not
receive replies:
8-6
On" on
M-10207-01, Reference Manual v2
page
8-2.