Clause / Requirement
13.8.3 Mandatory indications on an
alphanumeric display shall be legible for
at least one hour following the display of
a new indication of the voice alarm
condition and at least 5 minutes for fault
or disablement conditions, at 0,8 m
distance, in ambient light intensities from
5 to 500 lux, at any angle from the normal
to the plane of the display up to
13.9 Indication colors
13.9.1 The colors of the general and
specific indications from light emitting
indicators shall be
a red for indications of voice alarms;
2013.07 | V2.0 |
22.5º when viewed from each side,
and
15º when viewed from above and
below.
Installation and Operation manual
Compliance
Plena Voice Alarm System is
compliant.
The system status LED of Plena
Voice Alarm System call stations is
on (red) when the system is in the
voice alarm condition. The
indicators on the controller and
remote control panels are red. The
installer is responsible for
connecting a red light emitting
indicator to a 'Visual EVAC
indicator' output contact of the
Plena Voice Alarm System. All zone
indicators in emergency mode are
red.
Plena
Signature
Bosch Security Systems B.V.