Note: Avoid touching the bottom of the imaging unit.
Toner cartridge contacts removal
1
Remove the imaging unit. See
2
Remove the rear cover. See
3
Remove the rear screw (A) in the waste toner bottle sensor contact to allow access to the cable cover.
Note: The waste toner bottle sensor contact does not need to be unplugged or removed.
4
Remove the four screws (B) securing the cable cover, and remove the cable cover.
5
Rotate the printer to view the right side.
6
Lay the printer on its left side, and remove the screw (C) securing the spring contacts.
"Imaging unit (IU) removal" on page
"Rear cover removal" on page
Repair information
248
246.
290.