Use this mode to enter transmitter serial numbers. Press
ZONE NUMBER
A 02
Enter the 2-digit zone number of the first transmitter to have its serial number entered. The system will
announce the Voice Descriptor for the selected zone if it has been programmed.
[
] = Continue; system searches for zones not yet entered, (for zones 2 to 25 a zone type must be
entered) then advances to ENROLL SERIAL NUMBER prompt (1b).
00 = Exit Sequential mode, upon which the prompt "83" blinks
ENROLL MODE
zz
IA
0 = Advance to next unlearned zone.
1 = Enter now and proceed to SERIAL NUMER prompt (1b). For 4-button keys (zones 26-29, 30-33, 34-
37 and 38-41) the serial number will be learned to all four buttons.
2 = copy the previous serial number entry from the buffer.
IA LC
Note: Before you can copy a serial number you must first enter a serial number. If no serial is stored in the buffer and
3 = View existing serial number. (Only if "L" is displayed. If "L" is not displayed, panel will emit a long
beep. Each digit will be displayed and the keypad will beep once for digits 1-6 and three times for last
digit.
4 = Copy the 4-button key template set for zones 26 - 29 (includes all zone parameters except serial
numbers). Only valid on 4-button key zones 30-33, 34-37 and 38-41 that do not have serial numbers
learned. (Template acceptance is indicated by two beeps after copying. A single long beep emitted
when copying templates indicates the template is not valid.)
9 = Delete existing serial number. Go to the (1A) prompt. (For 4-button key zones 26-29, 30-33, 34-37
and 38-41, deletes all four at once.)
[
] = Advance to the next unlearned zone.
[#] = Return to previous prompt (1A).
SERIAL NUMBER
b
zz
I
This prompt can be used to enroll the transmitter serial number via RF transmission or manually.
RF Learning - Two (2) transmissions (two key depressions at least five second apart) will be required for
BR type or four (4) transmissions (fault, restore and fault, restore) for UR or RF type. BR type devices can
be enrolled only by transmission from BR devices. Likewise, UR and RF devices can only be enrolled by
b
I
transmission from a UR or RF device.
If the learned serial number has a different loop number than that entered in
announce the Voice Descriptor, if it is programmed, followed by two beeps and will return to Prompt
(1A) and "L" will be displayed.
If the loop number captured by RF transmission and that entered in
announce the Voice Descriptor, if it is programmed, followed by three beeps and return to Prompt (1A)
and "LC" will be displayed. No additional transmissions are needed for confirmation.
Manual Entry - Enter the 7-digit serial number printed on the transmitter. If you enter an incorrect digit,
press the [#] key to backup to prompt (1A) and start over. When all 7 digits are entered, press the [
key. If less than 7 digits are entered, the keypad will emit a single long beep and return to the (1A)
prompt without displaying the "L". If more than 7 digits have been entered, the first 6 digits will be saved
along with the last digit that was entered (entering 123456789 yields the serial number 1234569).
Note: If 52 seconds passes and no entry has been made, the system returns to prompt (1A).
DELETE ZONE PARAMETERS CONFIRMATION
F
0 = Discard the delete request.
1 = Confirm requested delete
a copy is attempted the panel will emit a long beep indicating an invalid operation.
.
✻ ✻ ✻ ✻ 83 ENHANCED SEQUENTIAL MODE
83 while in programming mode.
- 15 -
.
56 the system will
56 mode match, the system will
]