Ceiling Cassette-4Way Compact Type (Fdtc) - Mitsubishi Electric FDT125VNVF Technical Manual

Table of Contents

Advertisement

(2) Ceiling cassette-4way compact type (FDTC)

(a) Twin type
Model
FDTC100VNPVF
Indoor unit
Cool Mode
Outdoor
18 DB
21 DB
air temp.
12 WB
14 WB
DB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
25
8.93 7.25 9.64 7.16 10.31 7.68 10.62 7.63 10.95 7.58 11.61 7.94 12.27 7.80
27
8.86 7.21 9.64 7.16 10.34 7.69 10.65 7.64 10.96 7.59 11.57 7.92
29
8.80 7.18 9.50 7.10 10.17 7.62 10.49 7.58 10.81 7.53 11.45 7.88
31
8.73 7.15 9.35 7.03
33
8.22 6.72 8.58 7.08 9.21 6.96
35
8.05 6.63 8.44 7.01 9.06 6.90
37
7.92 6.57 8.30 6.94 8.91 6.83
39
7.78 6.49 8.16 6.87 8.75 6.76
41
7.64 6.42 8.02 6.81 8.60 6.69
43
7.50 6.35 7.88 6.74 8.45 6.62
FDTC100VSPVF
Model
Indoor unit
Cool Mode
Outdoor
18 DB
21 DB
air temp.
12 WB
14 WB
DB
TC
SHC
TC
SHC
11
13
15
17
19
21
23
25
8.93 7.25 9.64 7.16 10.31 7.68 10.62 7.63 10.95 7.58 11.61 7.94 12.27 7.80
27
8.86 7.21 9.64 7.16 10.34 7.69 10.65 7.64 10.96 7.59 11.57 7.92
29
8.80 7.18 9.50 7.10 10.17 7.62 10.49 7.58 10.81 7.53 11.45 7.88
31
8.73 7.15 9.35 7.03 9.99 7.54 10.32 7.51 10.66 7.47 11.32 7.83
33
8.22 6.72
8.58 7.08 9.21 6.96 9.82 7.47 10.16 7.44 10.51 7.41 11.19 7.78
35
8.05 6.63
8.44 7.01 9.06 6.90 9.64 7.39 10.00 7.37 10.36 7.35 11.07 7.74
37
7.92 6.57
8.30 6.94 8.91 6.83 9.46 7.32 9.79 7.29 10.13 7.26 10.80 7.64
39
7.78 6.49
8.16 6.87 8.75 6.76 9.28 7.24 9.59 7.21 9.90 7.17 10.53 7.54
41
7.64 6.42
8.02 6.81 8.60 6.69 9.09 7.16 9.38 7.12 9.68 7.08 10.26 7.45
43
7.50 6.35
7.88 6.74 8.45 6.62 8.91 7.09 9.18 7.04 9.45 7.00 9.99 7.35
Note(1) These data show average statuses.
Note(1)
Depending on the system control, there may be ranges where the operation is not conducted continuously.
Note(1)
These data show the case where the operation frequency of a compressor is fixed.
(2) Capacities are based on the following conditions.
(2)
Corresponding refrigerant piping length :7.5m
(2)
Level difference of Zero.
(3) Symbols are as follows.
TC : Total cooling capacity
SHC : Sensible heat capacity
FDT50VF (2 units)
Indoor air temperature
23 DB
26 DB
27 DB
16 WB
18 WB
19 WB
TC
SHC
TC
SHC
TC
SHC
8.12 6.48
8.59 6.95 8.82 6.90 9.07 6.85 9.56 7.20 10.06 7.07
8.50 6.64
9.00 7.12 9.26 7.08 9.52 7.02 10.06 7.38 10.60 7.25
8.88 6.81
9.42 7.30 9.69 7.25 9.98 7.20 10.56 7.55 11.14 7.42
9.26 6.99
9.84 7.48 10.12 7.42 10.43 7.38 11.05 7.73 11.67 7.60
9.46 7.08 10.05 7.57 10.34 7.51 10.65 7.46 11.29 7.82 11.92 7.68
9.65 7.17 10.25 7.65 10.56 7.60 10.88 7.56 11.52 7.90 12.16 7.77
9.65 7.17 10.28 7.66 10.59 7.62 10.91 7.57 11.56 7.92 12.21 7.78
9.99 7.54 10.32 7.51 10.66 7.47 11.32 7.83
9.82 7.47 10.16 7.44 10.51 7.41 11.19 7.78
9.64 7.39 10.00 7.37 10.36 7.35 11.07 7.74
9.46 7.32 9.79 7.29 10.13 7.26 10.80 7.64
9.28 7.24 9.59 7.21 9.90 7.17 10.53 7.54
9.09 7.16 9.38 7.12 9.68 7.08 10.26 7.45
8.91 7.09 9.18 7.04 9.45 7.00 9.99 7.35
FDT50VF (2 units)
Indoor air temperature
23 DB
26 DB
27 DB
16 WB
18 WB
19 WB
TC
SHC
TC
SHC
TC
SHC
8.12 6.48 8.59 6.95 8.82 6.90 9.07 6.85 9.56 7.20 10.06 7.07
8.50 6.64 9.00 7.12 9.26 7.08 9.52 7.02 10.06 7.38 10.60 7.25
8.88 6.81 9.42 7.30 9.69 7.25 9.98 7.20 10.56 7.55 11.14 7.42
9.26 6.99 9.84 7.48 10.12 7.42 10.43 7.38 11.05 7.73 11.67 7.60
9.46 7.08 10.05 7.57 10.34 7.51 10.65 7.46 11.29 7.82 11.92 7.68
9.65 7.17 10.25 7.65 10.56 7.60 10.88 7.56 11.52 7.90 12.16 7.77
9.65 7.17 10.28 7.66 10.59 7.62 10.91 7.57 11.56 7.92 12.21 7.78
Outdoor unit
FDC100VN
28 DB
31 DB
33 DB
20 WB
22 WB
24 WB
TC
SHC
TC
SHC
TC
Outdoor unit
FDC100VS
28 DB
31 DB
33 DB
20 WB
22 WB
24 WB
TC
SHC
TC
SHC
TC
166
-
-
'12 • PAC-T-174
(kW)
Heat Mode
Indoor air temperature
Outdoor
air temp.
DB
WB
16
18
SHC
-19.8 -20
5.64 5.62 5.60 5.58 5.56
-17.7 -18
5.97 5.95 5.92 5.90 5.87
-15.7 -16
6.30 6.27 6.25 6.22 6.19
-13.5 -14
6.66 6.63 6.60 6.57 6.54
-11.5 -12
7.03 6.99 6.96 6.93 6.90
-9.5
-10
7.39 7.36 7.32 7.29 7.25
-7.5
-8
7.75 7.72 7.68 7.64 7.60
-5.5
-6
7.92 7.88 7.85 7.80 7.76
-3.0
-4
8.10 8.05 8.01 7.97 7.92
8.27 8.22 8.18 8.13 8.08
-1.0
-2
8.44 8.39 8.34 8.29 8.24
1.0
0
8.52 8.47 8.42 8.37 8.32
2.0
1
3.0
2
9.08 9.03 8.98 8.94 8.90
5.0
4
10.21 10.15 10.09 10.08 10.07
7.0
6
11.33 11.27 11.20 11.22 11.23
9.0
8
11.78 11.71 11.64 11.62 11.59
11.5
10
12.23 12.16 12.09 12.02 11.94
13.5
12
12.91 12.83 12.75 12.65 12.60
15.5
14
13.59 13.50 13.42 13.29 13.26
16.5
16
13.93 13.84 13.75 13.61 13.59
PJA003Z383
Heat Mode
(kW)
Outdoor
Indoor air temperature
air temp.
DB
WB
16
18
-19.8 -20
5.64 5.62 5.60 5.58 5.56
SHC
-17.7 -18
5.97 5.95 5.92 5.90 5.87
-15.7 -16
6.30 6.27 6.25 6.22 6.19
-13.5 -14
6.66 6.63 6.60 6.57 6.54
-11.5 -12
7.03 6.99 6.96 6.93 6.90
-9.5
-10
7.39 7.36 7.32 7.29 7.25
-7.5
-8
7.75 7.72 7.68 7.64 7.60
-5.5
-6
7.92 7.88 7.85 7.80 7.76
-3.0
-4
8.10 8.05 8.01 7.97 7.92
-1.0
-2
8.27 8.22 8.18 8.13 8.08
1.0
0
8.44 8.39 8.34 8.29 8.24
2.0
1
8.52 8.47 8.42 8.37 8.32
3.0
2
9.08 9.03 8.98 8.94 8.90
5.0
4
10.21 10.15 10.09 10.08 10.07
7.0
6
11.33 11.27 11.20 11.22 11.23
9.0
8
11.78 11.71 11.64 11.62 11.59
11.5
10
12.23 12.16 12.09 12.02 11.94
13.5
12
12.91 12.83 12.75 12.65 12.60
15.5
14
13.59 13.50 13.42 13.29 13.26
16.5
16
13.93 13.84 13.75 13.61 13.59
PJA003Z383
(kW)
DB
20
22
24
A
(kW)
DB
20
22
24
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents