The GEM-DXRP1 is a "smart" user-
friendly, interactive menu-driven keypad
designed for your Napco control panel.
Its alphanumeric screen will not only
display the status of your system, but
will also give
you step-by-step
instructions to guide you through all
operations.
This booklet contains important
information about the operation of your
system with this GEM-DXRP1 Keypad.
Read it carefully and keep it handy for
Test your sounding device and backup battery
(These tests should only be performed on weekends or at a time
designated by your alarm company.)
1. While disarmed, press
A
2. Answer NO (press
F
the window.
3. Press YES (
E
) to execute the test. The alarm will sound for
about two seconds.
If the alarm does not sound, call for service.
If the battery is low, "LOW BATTERY E02-00 SERVICE" will appear
in the display indicating a low battery condition. Allow 24 hours for
the battery to recharge. If the trouble continues, call for service.
2
I N T R O D U C T I O N
future reference.
for an explanation of terms that may be
unfamiliar to you.
You'll probably find subjects
mentioned in this booklet that do not
apply to your system. Napco control
panels have such a wide variety of
features that few security systems, if
any, will ever need them all. Your alarm
professional has chosen appropriate
features for your particular needs.
IMPORTANT - TEST YOUR SYSTEM WEEKLY
.
) until "ACTIVATE BELL TEST" appears in
Check the Glossary
been configured, rest assured that it has
been carefully designed and engineered
to the highest industry standards.
assure optimum safety and security,
familiarize yourself with this equipment.
Periodically check its condition and
state of readiness by testing it at least
once a week in both the ac/battery and
battery-only modes (ask your alarm
professional how to make these tests).
Test your central station communicator
(Activate Dialer Test programmed?
1. Notify your Central Station of the impending test.
2. While disarmed, enter your User Code and press A.
3. Answer NO (press
F
in the window.
4. Press YES (
) to send a test code to the central station.
E
If the test is not successful, "COMM FAIL E03-00 SERVICE" will
display, indicating a communication failure. Call for service.
Note: Any subsequent successful transmission will clear a "Failure to
Communicate" system trouble
Regardless of how your system has
YES
NO)
) until "ACTIVATE DIALER TEST" appears
.
To