Maintenance

Checking Battery Specific Gravity

Use a hydrometer to check the battery specific gravity.
Checking Gravity
A. Hydrometer
B. Battery
NOTE: Do not take readings immediately after adding
distilled water, if the water and acid are not
thoroughly mixed, the reading may not be accurate.
Check the hydrometer readings against this chart.
SPECIFIC GRAVITY
@ 80° F (27°C)
1.265
1.225
1.190
1.155
1.120
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80
(27
°
C), the reading must be temperature corrected.
To find the corrected specific gravity reading when the
temperature of the battery electrolyte is other than
°
°
80
F (27
): Add (+) to the specific gravity reading 0.004
(4 points), for each 10
°
F (6
Subtract (-) from the specific reading 0.004 (4 points),
°
°
for each 10
F (6
C) below 80

To Charge The Batteries

When servicing machine, avoid contact with
battery acid.
Lors de l'entretien de la machine, évitez tout
contact avec l'acide de batterie.
24
BATTERY CONDITION
100% CHARGED
75% CHARGED
50% CHARGED
25% CHARGED
DISCHARGED
°
F
°
C) above 80
°
(27
°
C).
°
°C).
F (27
86400370 Manual Operators - EURO 24V Standard
Batteries emit hydrogen gas. Explosion or fire
can result. Keep sparks and open flame away.
Keep covers open when charging.
Les batteries émettent du gaz hydrogène. Une
explosion ou un incendie peut en résulter.
Maintenez les étincelles et les flammes nues à
l'écart. Gardez les carters ouverts lors du charge-
ment.
Wear eye protection and protective clothing when
working with batteries.
Portez des lunettes de protection et des vêtements
de protection lorsque vous travaillez avec des
batteries.
Charge batteries in a well ventilated area. Leave
the battery cover open.
Chargez les batteries dans un endroit bien ventilé
Use a 24 volt, 18 amp maximum output or 25 amp
(depending on the size of the batteries), DC charger
which will automatically shut off when the batteries are
fully charged.
1. Stop the machine in a clean, well ventilated area
next to the charger.
2. Turn "OFF" machine.
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, turn off machine
and remove key.
3. Raise the battery cover.