No.
Step
12 Clean the cleaner assembly:
• Side scarper
13 Clean the duplexing unit:
• Duplex horizontal registration
sensor
14 Clean the copyboard glass.
15 Make test copies.
16 Make sample copies.
17 Press the leakage breaker test
switch to make sure that the
breaker operates normally. There-
after, turn off the power switch,
and shift the lever to ON position;
then, turn on the power switch.
Check to make sure that
the grounding is correct;
otherwise, leakage may
not trigger the leakage
breaker.
18 Put the sample copies in order, and
clean up the area around the ma-
chine.
19 Record the latest counter readings.
20 Fill out the service Book, and re-
port to the person in charge.
5-12
Checks
Press the test switch while
the power switch is ON and
the lever [1] of the leakage
breaker is at ON; if normal,
the lever should shift to OFF
position to cut off the power.
(Pay attention to the orienta-
tion whenever replacing the
breaker. If you have replaced
the breaker, be sure to check
its operation.)
Record the results of the
check made on the leakage
breaker in the Service Book.
T05-300-03
COPYRIGHT© 2001 CANON INC.
F05-300-03
2000 2000 2000 2000
CANON iR8500 REV.0 MAR. 2001
Remarks