11-4. Self-Diagnosis by Remote Controller (Check Code)

1. The self-diagnosis by the check code is performed while items B to E blocks are displayed.
2. When turning the operation mode on the remote controller to the service mode, and operating the remote
controller, the controller of the indoor unit can self-diagnose operation of the protection circuit by displayed
contents (check code) on the remote controller, by whether all the lamps flash (5Hz) and the receiving
sound (Beep, Beep, Beep ... for 10 seconds) is heard. The timer lamp usually flashes (5Hz) during self-
diagnosis.
11-4-1. Self-Diagnosis
1. Wireless remote controller
CHK
PRESET
START/STOP
FAN
MODE
AUTO
SWING
ECO
Hi-POWER
TIMER
TIMER
FIX
MEMO
ON
OFF
SET
FILTER
RESET CLOCK CHECK
Alphanumeric characters are
used for the check codes.
is 5.
is 6.
is A.
is B.
is C.
is D.
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
1
Push the CHK button by something with thin edge.
• Check
2
Push
If it is normal, the receiving sound "Beep" is heard
every pushing it and check code in the indication
part of the remote controller changes.
The timer lamp of the air conditioner flashes.
(5 times for 1 second)
• Check all of 35 check codes (
• Push
If a trouble occurs, the receiving sound "Beep"
changes to Beep, Beep, Beep
(continues for approx. 10 seconds).
CLR
Check the check code in the indication part
of the remote controller.
• 2-digits alphanumeric characters are displayed in the
• All the lamps of the air conditioner flash
3
To release the self-diagnosis function,
push
Pushing the button once displays the operation stop, and
pushing the button twice returns the display before check.
www.heronhill.co.uk
is displayed in the indication
part of the remote controller.
toward the indoor unit one by one.
to return to the objective code if passed.
indication part of the remote controller.
(5 times for 1 second).
button.
START/STOP