5. Voltage
Connect the pocket tester (DC20 V) to the
bulb socket connector.
At flasher light (left)
Tester (+) lead ! Chocolate lead
Tester (–) lead ! Black terminal
At flasher light (right)
Tester (+) lead ! Dark green lead
Tester (–) lead ! Black terminal
Turn the main switch to on.
Turn the turn switch to left or right.
Check for voltage (12 V) on the "Chocolate"
lead and "Dark green" at the flasher light ter-
minal.
This circuit is not faulty.
1
3
2
3
MEETS
SPECIFICATION
SIGNAL SYSTEM
OUT OF SPECIFICATION
6. Wiring connection
Wiring circuit from the turn switch to bulb
socket connector is fault. Repair.
Refer to "CIRCUIT DIAGRAM".
86