4
PARAMETER
4.1
Parameter list
The following parameters are used for the plug-in option (FR-A8AX).
The FR-A8AX does not function with the initial setting. When a value other than "9999" is set in Pr.304, digital input is enabled.
Set the following parameters according to applications.
Pr.
Pr.
group
300
D600
BCD input bias
301
D601
BCD input gain
302
D602
BIN input bias
303
D603
BIN input gain
Digital input and analog input
304
D604
compensation enable/disable selection
305
D605
Read timing operation selection
329
,
D606
,
Digital input unit selection
447
,
D620
,
Digital torque command bias
448
,
D621
,
Digital torque command gain
804
D400
Torque command source selection
Parameters which can be displayed when the plug-in option (FR-A8AX) is mounted.
For Pr.329, write is disabled during operation even when "2" is set in Pr.77. To change the parameter setting value, stop the operation.
Also, parameter clear is invalid.
The initial values differ for the FM type and CA type of the inverter.
The setting range of Pr. 304 differs according to the inverter used. (Refer to
These parameters can be set for the FR-A800 series only.
20
PARAMETER
Name
Setting range
0 to 590 Hz
0 to 590 Hz, 9999
0 to 590 Hz
0 to 590 Hz, 9999
0 to 4, 10 to 14, 9999
0, 1, 10
0, 1, 2, 3
0 to 400%
0 to 400%, 9999
0, 1, 3 to 6
Minimum
setting
Initial value
increments
0.01 Hz
0 Hz
0.01 Hz
60 Hz/50 Hz
0.01 Hz
0 Hz
0.01 Hz
60 Hz/50 Hz
1
9999
1
0
1
1
1%
0
1%
150%
1
0
page
21)
Refer to
page
25
25
25
25
21,
27
22
26
27
27
27