Mitsubishi Electric FR-A8AX Instruction Manual page 17

800 series
Hide thumbs Also See for FR-A8AX:
Table of Contents

Advertisement


Use terminal SD or PC on the inverter.

AY41 type unit requires 24 VDC power.
Example of connection with the output module (AY41 type) of Mitsubishi programmable controller. For details on the output module, refer
to the Instruction Manual of the output module manual.

The control logic is the same as that of the inverter.
When the logic of the inverter is changed, the option logic also changes. Refer to the Instruction Manual of the inverter for how to switch
the control logic of the inverter.
NOTE
• As the input signals are at low level, use two parallel micro signal contacts or a twin contact for relay contact inputs to
prevent a contact fault.
• A transistor of the following specifications should be selected for the open collector signal:
Electrical characteristics of the transistor used
 10 mA
·I
c
·Leakage current: 100 µA maximum
 30 V
·V
CE
 10 mA, V
·I
c
CE (sat)
Micro signal contacts
voltage is 3 V maximum
Twin contacts
CONNECTION DIAGRAM AND TERMINAL
3
17