Edger Blade Replacement - Echo PE-225 Operator's Manual

Power edger
Hide thumbs Also See for PE-225:
Table of Contents

Advertisement

PE-225
Gear Housing
1. Remove plug (A) and add grease to gear housing. Do not
over-fill.
2. Replace plug and tighten securely.
Drive Shaft
1. Loosen two (2) screws (B) and remove center locating
screw (C). Pull gear box and shield from drive shaft housing.
2. Pull flexible cable from the drive shaft housing, wipe clean
and re-coat with a thin coating (15 ml [1/2 oz.]) of grease.
3. Slide the flexible cable back in the drive housing. DO NOT
get dirt on the flex cable.
4. Install the gear housing and shield assembly. Align locating
screw hole with hole in drive shaft housing.
5. Tighten screws securely.

Edger Blade Replacement

Level 1.
Parts Required:
Blade, new split pin
Note: Replace blade when it is bent, damaged, or worn shorter than 6 inches.
1. Remove split pin (A).
X7722279201
©3/2015 ECHO Inc.