Technical Data; Arc Technical And Physical Data (Only Cooling) - York ACTIVA 100 Installation Manual

Roof top air conditioners
Table of Contents

Advertisement

1
Installation manual
1.4

Technical data

1.4 Technical data

1.4.1 ARC technical and physical data (Only cooling)

ARC/ARG models
Net cooling capacity
Cooling capacity (1)
Rated absorbed power
Net EER
Heating
Optional heating element heating capacity (400 V) (2)
Circuits
Rated/start-up current
Compressors
Type and quantity (per circuit)
Degree of protection
Coolant
Charge (per circuit)
(R-410A)
Power supply
Rated air flow
Rated static pressure / maximum with rated flow
Maximum flow rate
Indoor fan (3)
Minimum flow rate
Motor (IP55) Maximum power / Quantity
Maximum current
Number of elements
Indoor coil (evaporator)
Distance between fins
Front surface
Quantity per unit
Air filters (G4)
Dimensions
Diameter/number
Total rated flow
Outdoor fan
(Data per circuit)
Motor (IP54)
Rated current
Number of elements
Outdoor coil (condenser)
Distance between fins
(Data per circuit)
Front area
Height
Net dimensions (4)
Length
Width
Net weight (basic unit without
accessories) (4)
Total rated power
Total rated current
Total maximum power
Electrical features of the unit
Total maximum current
Circuit breaker (K Curve) (5)
Minimum cable section (6)
Data in compliance with Eurovent conditions, summer: indoor 27 °C TS/19 °C TH ‑ outdoor TS 35 °C. Winter: Indoor TS 20 °C, outdoor TS 7 °C / TH 6 °C (TS Dry-bulb thermometer; TH Wet-
(1)
bulb thermometer), with vertical ducts, rated air flow and pressure.
Net EER = Net cooling capacity / Total absorbed power (according to Eurovent).
(2)
Add the inside motor consumption to find the total calorific capacity.
Indoor
fan, see on page 21 .
(3)
See
(4)
Consider the additional weight of options and accessories. To do so, see
Circuit breaker with K curve, according to DIN, VDE 0660-104. Section of cables for the power supply line based on copper conductors, 105 °C. The circuit breaker and the section of power
(5) and
supply cables indicated are for guidance. They should be adjusted based on the requirements of each installation, distance between units, fall in planned voltage and on the application of the
(6)
current regulations with respect to the country where the unit is being installed.
6
100
kW
108
kW
34
3,46
kW
37 ‑ 50
No.
A
4 x 13 / 111
kg
20
V/ph/Hz
3
m
/h
19000
Pa
m
3
/h
22000
3
m
/h
16000
kW
5,5 / 1
A
12,5
No.
mm
1,81
m
2
3,5
No.
mm
823 x 730 x 48
mm
800 / 1
3
m
/h
18000
kW
1,9
A
3,3
No.
3 (x 2)
mm
2,11
m
2
1,86 (x 2)
mm
mm
4036
mm
2250
kg
kW
34
A
65
kW
49
A
88
A
100
2
mm
3 x 35
Weight options and
accessories, see on page 8 .
125
150
122
149
41
59
3,21
3,13
37 ‑ 50 ‑ 60
2
2
4 x 15 / 118
4 x 20 / 140
Scroll x 2 (1 Tándem)
IP21
20
25
400 / 3 / 50
21000
27000
25000
32000
18000
22000
4 / 2
12,5
9,5 x 2
4
1,81
5,2
6
823 x 880 x 48
800 / 2
36000
1,9 (x 2)
3,3 (x 2)
3 (x 2)
2,11
2,62 (x 2)
1862 + 280 ventilador
5085
2250
41
59
75
110
57
74
101
137
125
160
3 x 50
3 x 50
175
169
64
2,91
4 x 24 / 198
25,5
30000
35000
25000
9,5 x 2
64
125
85
157
200
3 x 70

Advertisement

Table of Contents
loading