Remote Run Time Commands; Abeep; Adbeep; Akeyr - AMX MIO-R4 Instruction Manual

Hide thumbs Also See for MIO-R4:
Table of Contents

Advertisement

Remote Run Time Commands

A device must first be defined in the NetLinx programming language with values or the Device: Port: System. In all programming
examples - Remote is used in place of these values.
Serial Commands are used in the AxcessX Terminal Emulator mode. These commands are case insensitive.
Remote Run Time Commands

ABEEP

ADBEEP

AKEYR

@AKP

@AKR

BEEP

BRIT

DBEEP

Mio Modero R-4 Remote - Instruction Manual
Output a single beep even if beep is Off.
Syntax:
SEND_COMMAND <DEV>,"'ABEEP'"
Example:
SEND_COMMAND Device,"'ABEEP'"
Outputs a beep of duration 1 beep even if beep is Off.
Outputs a double beep even if beep is off.
Syntax:
SEND_COMMAND <DEV>,"'ADBEEP'"
Example:
SEND_COMMAND Device,"'ADBEEP'"
Outputs a double beep even if beep is Off.
Remove the Keyboard/Keypad. Remove keyboard or keypad that was displayed using 'AKEYB', 'AKEYP', 'PKEYP', @AKB,
@AKP, @PKP, @EKP, or @TKP commands.
Syntax:
SEND_COMMAND <DEV>,"'AKEYR'"
Example:
SEND_COMMAND Device,"'AKEYR'"
Removes the Keyboard/Keypad.
Pop up the keypad icon and initialize the text string to that specified. Keypad string is set to null on power up and is stored
until power is lost. The Prompt Text is optional.
Syntax:
SEND_COMMAND <DEV>,"'@AKP-<initial text>;<prompt text>'"
Variables:
• initial text = 1 - 50 ASCII characters.
• prompt text = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Device,"'@AKP-12345678;ENTER PASSWORD'"
Pops up the Keypad and initializes the text string '12345678' with prompt text 'ENTER PASSWORD'.
Remove the Keyboard or Keypad. Remove keyboard or keypad that was displayed using 'AKEYB', 'AKEYP', 'PKEYP', @AKB,
@AKP, @PKP, @EKP, or @TKP commands.
Syntax:
SEND_COMMAND <DEV>,"'@AKR'"
Example:
SEND_COMMAND Device,"'@AKR'"
Removes the Keyboard/Keypad.
Output a beep.
Syntax:
SEND_COMMAND <DEV>,"'BEEP'"
Example:
SEND_COMMAND Device,"'BEEP'"
Outputs a beep.
Set the remote brightness.
Syntax:
"'BRIT-<brightness level>'"
Variables:
• brightness level = 0 - 100.
Example:
SEND COMMAND Device,"'BRIT-50'"
Sets the brightness level to 50.
Output a double beep.
Syntax:
SEND_COMMAND <DEV>,"'DBEEP'"
Example:
SEND_COMMAND Device,"'DBEEP'"
Outputs a double beep.