11

11 Device Information

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
2.2
Installation location
3

Performance data

3.1
Operating temperature limits:
Heating water flow/return flow
Air
3.2
Temperature spread of heating water (flow/return flow) at A7 / W35
3.3
Heat output / COP
3.4
Sound power level
3.5
Sound pressure level at a distance of 10 m (air outlet side) dB(A)
3.6
Heating water flow with an internal pressure differential of m³/h / Pa
3.7
Air flow rate
3.8
Refrigerant; total filling weight
3.9
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
5.4
Nominal current A2 W35 / cos
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
7.4
Controller internal/external
1. See operating limits diagram
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature
and 55 °C heating water flow temperature.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump manager must always be ready for operation.
EN-8
1
°C / °C
°C
2
at A-7 / W35
kW / ---
2
at A-7 / W45
kW / ---
2
at A2 / W35
kW / ---
2
at A7 / W35
kW / ---
2
at A7 / W45
kW / ---
2
at A10 / W35
kW / ---
dB(A)
m³/h / Pa
type / kg
type / litres
H x W x L cm
Inch
kg
V / A
2
A2 W35
kW
A
A / ---
4
LA 8AS
IP 24
Outdoors
Up to 58 / above 18
-25 to +35
8.9
5.1 / 2.5
6.6 / 3.1
8.3 / 3.7
8.8 / 3.8
62
32
0.8 / 2700
2500
R404A / 1.9
Polyolester (POE)/ 1.5
128 x 75 x 65
G 1'' external
166
400 / 16
2.24
19.5
3.8 / 0.8
3
Automatic
Reverse cycle
Yes (heated)
Yes
1
External
5
4.9 / 2.4
4.8 / 2.0
6.5 / 3.0
8.2 / 3.6
7.9 / 3.0
8.7 / 3.7
1.4 / 9000
2.28
3.9 / 0.8

Advertisement