Minimum Alcove Clearance and Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84"
Maximum depth of alcove - 36"
NOTE: This clearance is also required for air space between the appliance and wall/ceiling.
Unit
Medium F2400M with Airmate
with Rear Deflector
Medium S2400M Step Stove

Floor Protection

(Ember Protection only required)
A combustible floor must be protected by non-combustible
material (like tile, concrete board, or certified to UL-1618 or
as defined by local codes) extending beneath the heater and
a minimum of 6" (152mm) from each side and minimum 16"
(406mm) from the front face of the stove and minimum 6"
(or the rear clearance to combustibles whichever is smaller)
from the rear of the stove.
When installed with horizontal venting, non-combustible floor
protection must beneath the flue pipe and extend 2" (51mm)
beyond each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
Stove
F2400M
Step Stove
S2400M
Minimum Overall Depth (Y) of Floor Protector
Unit
Medium F2400M with Airmate
with Rear Deflector
Medium S2400M Step Stove
* The rear clearance to combustibles is less than 6" (for corner installations the rear corners may be angled to take advantage of the closer clearances
From Unit
G
H
15" (381 mm)
5.5" (139 mm)
15" (381 mm)
6.5" (165 mm)
15" (381 mm)
5.5" (139 mm)
36" (914 mm)
36" (914 mm)
Residental `C`Vent
Residential
Close Clearance
Y
Z
Y
46" (1168 mm)
6" (152 mm)
45"* (1143 mm)
46" (1168 mm)
6" (152 mm)
45" (1143 mm)
46" (1168 mm)
6" (152 mm)
45"* (1143 mm)
From Corner
I
J
27" (685 mm)
12" (304 mm)
27" (685 mm)
13" (330 mm)
27" (685 mm)
12" (304 mm)
NOTE: In Canada, floor protection must extend 18" (450mm) to the
front and 8" (200mm) to each side and back of the stove.
Mobile Home
Close Clearance
Z
Y
5" (127 mm)
45" (1143 mm)
5" (127 mm)
45" (1143 mm)
5" (127 mm)
45" (1143 mm)
installation
From Flue Center-Line
K
L
54" (1371 mm)
48" (1219 mm)
54" (1371 mm)
49" (1244 mm)
54" (1371 mm)
48" (1219 mm)
Alcove
Z
Y
5" (127 mm)
45"* (1143 mm)
5" (127 mm)
45"* (1143 mm)
5" (127 mm)
45"* (1143 mm)
Regency 2400 Freestanding Woodstove
|