Minimum Clearance To Combustibles; Floor Protection - Regency F2402M Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

INSTALLATION
Use only the instructions and clearance dimensions on
this page for heaters to be installed in Australia.
The Regency F2402M has been tested by the AHHA Testing Laboratory
and conforms to AS/NZS 2918:2001, Report No. ATL19-04.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the airmate or the
rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner,
and from the rear heat shield to a back wall.
Residential Installation Clearances to Combustible Walls
Unit
Medium F2402M
with Airmate*
with Rear Deflector*
*Airmate fitted, and 900mm long half round enamelled mild steel flue shield or half perforated decromesh
flue shield fitted
*Rear firebox shield extension fitted, and full length half perforated decromesh flue surround or 900mm
long half round enamelled mild steel flue shield fitted.
Flue systems tested:
Acorn Special Insulated
FLOMET Super Single
Shamic 1A
Floor Protector:
6mm thick fibre cement sheet with thermal conductivity 0.41 W/m degree K underneath heater extending 300mm
in front and 200 mm from the sides of the firebox opening.
8
AUSTRALIA ONLY
AUSTRALIA ONLY
From Unit
A
450mm
450mm
IMPORTANT
The Regency F2402 has been tested with the flue kits listed below.
A default flue kit as listed in AS/NZS 2918:2001 may also be used.
These are the only flue kits certified for use with this heater for
installation in Australia.
From Corner
B
C
125mm
150mm
150mm
225mm
From Flue Center-Line
D
E
755mm
290mm
755mm
315mm
Regency Freestanding Woodstove
F
445mm
555mm