Carrier FED B Series Installation Instructions Manual
Carrier FED B Series Installation Instructions Manual

Carrier FED B Series Installation Instructions Manual

Downflow electric furnace

Advertisement

FED "B" Series
Downflow Electric Furnace
Installation Instructions & Homeowner's Information
Approved for use in manufactured homes.
NOTE: Read the entire instruction manual before starting the
installation.

Table of Contents

Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
POSITION UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ELECTRICAL CONNECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Line Voltage Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Thermostat Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Thermostat Wiring Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 4
(applicable to on-site HVAC contractor) . . . . . . . . . . . . . . . . . . . . 4
Ground Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Filtered Grille Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
(applicable to on-site HVAC contractor) . . . . . . . . . . . . . . . . . . . . 5
Sequence of operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Continuous Fan (Whole House Ventilation) . . . . . . . . . . . . . . . . . 5
Electric Heat or Emergency Heat Mode . . . . . . . . . . . . . . . . . . . . 5
HOMEOWNER'S INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . 11
THERMOSTAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Heating Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cooling Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Temperature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Fan Control (Whole House Ventilation) . . . . . . . . . . . . . . . . . . . 11
Before Requesting a Service Call: . . . . . . . . . . . . . . . . . . . . . . . . 11
REGULAR MAINTENANCE REQUIREMENTS . . . . . . . . . . . . . 11
Indoor Unit Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Outdoor Unit Coils. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Painted Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or
use can cause explosion, fire, electrical shock or other conditions which
may cause death, personal injury or property damage. Consult a
qualified installer, service agency, or your distributor or branch for
information or assistance. The qualified installer or agency must use
factory-authorized kits or accessories when modifying this product.
Refer to the individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses, protective clothing and
work gloves. Use quenching cloths for brazing operations. Have fire
extinguisher available. Read these instructions thoroughly and follow all
warnings or cautions attached to the unit. Consult local building codes
and the applicable editions of the National Electrical Codes (NEC)
NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical Code
CSA C22.1.
Recognize safety information. This is the safety-alert symbol
you see this symbol on the unit and in instructions or manuals, be alert to
the potential for personal injury.
Understand the signal words DANGER, WARNING and CAUTION.
These words are used with the safety-alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury or
death. WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices, which
may result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing, modifying or servicing system, always turn off main
power to system. There may be more than one disconnect switch. Lock
out and tag switch with a suitable warning label.
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear
appropriate protective clothing and gloves when handling parts.

INTRODUCTION

Model FED has been designed for downflow applications. Models are
available for electric heat sizes 10 kW - 20 kW. All models use an ECM
motor.
FED models contain a factory supplied replaceable air filter.

LOCATION

Select the best position which suits the installation site conditions. The
location should provide adequate structural support, space in the front of
the unit for service access, clearance for return air and supply duct
connections, space for refrigerant piping connections and condensate
drain line connections.
NOTE: Internal filter can be accessed from a separate filter door.
CAUTION
. When

Advertisement

Table of Contents
loading

Summary of Contents for Carrier FED B Series

  • Page 1: Table Of Contents

    FED “B” Series Downflow Electric Furnace Installation Instructions & Homeowner’s Information Approved for use in manufactured homes. Follow all safety codes. Wear safety glasses, protective clothing and work gloves. Use quenching cloths for brazing operations. Have fire NOTE: Read the entire instruction manual before starting the extinguisher available.
  • Page 2: Position Unit

    FED “B” Series: Installation Instructions & Homeowner’s Information 2. Apply a bead of UL 181 rated caulk or approved duct mastic around CAUTION the perimeter of the hole, and install the plenum and make appropriate connections to the ductwork. See Fig.
  • Page 3: Electrical Connections

    FED “B” Series: Installation Instructions & Homeowner’s Information IMPORTANT: Make certain that the unit is level or pitched slightly WARNING toward the front to ensure proper unit operation. 9. After the unit is installed, cover the top to prevent construction ELECTRICAL SHOCK HAZARD debris from entering.
  • Page 4: Thermostat Wiring Connections

    FED “B” Series: Installation Instructions & Homeowner’s Information Thermostat Wiring Connections Ground Connections For complete electric furnace electrical specs, see Table WARNING Fig. • R = 24V ELECTRICAL SHOCK HAZARD • G = Continuous Fan Failure to establish uninterrupted or unbroken ground could result in •...
  • Page 5: Filtered Grille Applications

    FED “B” Series: Installation Instructions & Homeowner’s Information Fan speed selection is done at the fan motor. To change motor speeds, reposition wire at fan motor speed terminals labeled 1-2-3. See Fig. Units with or without electric heaters require a minimum CFM. Refer to the unit wiring label to ensure that the fan speed selected is not lower than the minimum fan speed indicated.
  • Page 6 FED “B” Series: Installation Instructions & Homeowner’s Information Table 3 – Airflow Performance - without Cooling Coil (CFM) Total Static (inches water column) Size Blower Speed 0.10 0.20 0.30 0.40 0.50 0.60 Tap 5 1123 1081 1032 Tap 4 1015 FED002410* Tap 3 1015...
  • Page 7 FED “B” Series: Installation Instructions & Homeowner’s Information Table 5 – Electrical Data, Fan Coil Only, with Electric Heat Model Heater kW Circuit Motor Amps Heater Amps Min Circuit Amps Breaker Size FED002410* 10 KW SINGLE 53.6 FED003610* 10 KW SINGLE 55.1 A (L1,L2)
  • Page 8 FED “B” Series: Installation Instructions & Homeowner’s Information CIRCUIT CIRCUIT BREAKER BREAKER HI or Y2 Circulating Fan Heating Tap Do NOT use for electric heating Do NOT use for HI or Y2 HIGH STATIC COOLING heating without coil High static cooling only 9.
  • Page 9 9. RED wire / WHT stripe to QC1A, BLK wire / WHT stripe to QC2A. A190012E Fig. 13 – 12 kW / 15 kW Unit Wiring Diagram © 2022 Carrier. All rights reserved. Edition Date: 11/22 Catalog No: IM-FED-02 A Carrier Company Replaces: 496 01 5504 01 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
  • Page 10 FED “B” Series: Installation Instructions & Homeowner’s Information HI or Y2 HI or Y2 A190050D Fig. 14 – 20 kW Wiring Diagram © 2022 Carrier. All rights reserved. Edition Date: 11/22 Catalog No: IM-FED-02 A Carrier Company Replaces: 496 01 5504 01...
  • Page 11: Homeowner's Information

    4. Inspect the coils and fins on the outdoor unit. Clean away any obstructions (grass clippings, leaves, dirt, dust, or lint). © 2022 Carrier. All rights reserved. Edition Date: 11/22 Catalog No: IM-FED-02 A Carrier Company Replaces: 496 01 5504 01 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

This manual is also suitable for: