Carrier OBM112 Series Installation Instructions Manual
Carrier OBM112 Series Installation Instructions Manual

Carrier OBM112 Series Installation Instructions Manual

Multipoise oil furnace
Table of Contents

Advertisement

Available languages

Available languages

OBM112
OVM112
Copyright 2012 CAC / BDP D 7310 W. Morris St. D Indianapolis, IN 46231
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Installation Instructions
THIS BOOKLET CONTAINS
IMPORTANT INFORMATION
C
US
INPUT CAPACITIES 95,200---112,000
INSTALLER:
booklet to install the appliance and affix this
booklet
installation.
USER:
Keep this booklet of information for
future reference.
SERVICER: Use the information in this booklet
to service the appliance and affix the booklet
adjacent to the appliance after servicing.
A09611
Use of the AHRI Certified TM Mark indicates a
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
Printed in U.S.A.
Edition Date: 03/13
MULTIPOISE OIL FURNACE
Use the information in this
adjacent
to
the
Catalog No: IM---OBM112---04 / X 40168 Rev. G
Replaces: IM--- OBM112--- 03
appliance
after

Advertisement

Table of Contents
loading

Summary of Contents for Carrier OBM112 Series

  • Page 1 OBM112 MULTIPOISE OIL FURNACE INPUT CAPACITIES 95,200---112,000 OVM112 Installation Instructions THIS BOOKLET CONTAINS IMPORTANT INFORMATION INSTALLER: Use the information in this booklet to install the appliance and affix this booklet adjacent appliance after installation. USER: Keep this booklet of information for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS FIGURES SAFETY REGULATIONS........3 SAFETY LABELING AND WARNING SIGNS..3 Figure 1: Location and dimensions of ventilation air IMPORTANT INFORMATION....... 3 openings in a closet door...........4 DETECTION SYSTEMS ......... 3 Figure 2: Upflow installation ..........4 DANGER OF FREEZING........3 Figure 3: Downflow installation ........5 Figure 4: Horizontal installation ........5 INSTALLATION ...........
  • Page 3: Safety Regulations

    Before calling for service, be sure to have the SAFETY REGULATIONS information page of your manual close by in order to be able to provide the contractor with the SAFETY LABELING AND required information, such as the model and WARNING SIGNS serial numbers of the furnace.
  • Page 4: Installation

    The unit must be installed in an area where the ambient INSTALLATION and return air temperatures are above 15°C (60°F). In addition, the furnace should be installed as closely as This furnace is a true multi-position unit, in that it will possible to the vent, so that the connections are direct function in an upflow, downflow or horizontal configuration and kept to a minimum.
  • Page 5: Electrical System

    2.2.2 Downflow Installation ELECTRICAL SYSTEM When the furnace is installed in the downflow position on a CAUTION combustible floor, the clearances from combustibles must The exterior of the unit must have an uninterrupted adhered downflow base DFB-103 ground to minimize the risk of bodily harm, if ever an KLASB0901DET can be used to ensure these clearances.
  • Page 6: 2.5 Installation Of The Burner

    Install the nozzle (refer to Technical Specifications, Figure 6: Thermostat wiring, heating and air conditioning (Table 6); with ECM variable speed motor Check the electrode settings; Make the electrical connections; Complete oil line connections. 2.5.1 Nozzles The burner comes equipped with an appropriate nozzle. However, if another size or a replacement nozzle is required, use the manufacturer’s recommended spray angle and type a shown in Table 1 and based on a pump...
  • Page 7: Blocked Vent Shut-Off Device (Bvso) For Chimney Venting

    2.6.1 Masonry chimney Start up the burner; Remove the three-pole plug from the BVSO outlet on This furnace can be vented into an existing masonry chimney. the furnace; However, the unit must not be vented into a chimney into The burner must shut-off immediately, while the which a solid fuel burning furnace is already being vented.
  • Page 8: Ducting

    Halogen type refrigerants; 2.10 DUCTING Cleaning solvents (such as perchloroethylene); WARNING Printing inks, paint removers, varnishes, etc. ; Hydrochloric acid; Poisonous carbon monoxide gas hazard. Solvent based glue; DO NOT draw return air from inside a closet or utility Antistatic fabric softeners for clothes dryers; room.
  • Page 9: Supply Air Adjustments (Ecm Variable Speed Motors)

    Figure 8: Blower start/stop delays, board #1158 Table 5: Delay adjustments, heating mode SW4 – Delay Input DIP Switch Positions USGPH POSITION 0.68 0.80 2.13 INSTALLATION OF ACCESSORIES WARNING 2.12 SUPPLY AIR ADJUSTMENTS Electrical shock hazard. (ECM VARIABLE SPEED MOTORS) Turn OFF electrical power at the fuse box or service On units equipped with ECM variable speed blower motors, panel before making any electrical connections and...
  • Page 10: Operation

    other control is required, in order to prevent the simultaneous CHECKS AND ADJUSTMENTS operation of the furnace and the heat pump. It also prevents a direct transition from heating by way of the heat pump to 3.3.1 Purging The Oil Line heating with oil.
  • Page 11: Maintenance

    horizontal position and the face of the damper vertical for proper functioning (see instructions included with the damper.) CAUTION After the furnace has been firing for at least five minutes, the Do not attempt to start the burner when excess oil has draft regulator should be set to between -0.025"...
  • Page 12: Cleaning The Blocked Vent Shut-Off Device (Bvso)

    After the cleaning replace the heat exchanger baffles, flue CHANGING THE AIR FILTER collar plate and oil burner; Dirty filters have an impact on the efficiency of the furnace Readjust the burner for proper operation. and increase fuel consumption. CLEANING THE BLOCKED VENT Air filters should be changed at least once a year.
  • Page 13: Furnace Information

    5 FURNACE INFORMATION Model: Serial number: Furnace installation date: Service telephone #-Day: Night: Dealer name and address: START-UP RESULTS Nozzle: Pressure: lb/po Burner adjustments: Primary air Fine air Drawer Assembly Smoke scale: (Bacharach) Gross stack temperature: °F Ambient temperature: °F Chimney draft : "...
  • Page 14: Motor

    Table 6: Technical Specifications 112 Series, multi-position models UNITS 1/2 HP 4-SPEED MOTOR UNITS WITH 1/2 HP ECM MOTOR RATING AND PERFORMANCE Firing rate (USGPH)* 0,68 0,80 0,68 0,80 Input (BTU/h)* 95 200 112 000 95 200 112 000 Maximum Heating capacity, (BTU/h)* 81 000 94 000 81 000...
  • Page 15: Table 7: Airflow Data, With 1/2 Hp, Ecm Motors

    Table 7: Airflow Data, models with 1/2 HP, ECM motors OIL HEA TING MODE 24 VAC input (R) on W only SW1- HEAT HEAT INPUT CFM with SW3-ADJ CFM with SW3-ADJ CFM with SW3-ADJ DIP switch position (USGP H) DIP switch position A DIP switch position B DIP switch position C 0,68...
  • Page 16: Table 9: Min. Clearances From Combustible Material

    Table 8: Airflow Data, model with 1/2 HP 4 speed motor E X TE RN AL S T AT IC P R E S S U R E W IT H A IR FI L TE R B L O W E R S P E E D 0 .
  • Page 17: Figure 9: Furnace Dimensions

    Figure 9: Furnace Dimensions...
  • Page 18: Figure 10: Wiring Diagram 4 Speed Motor (Psc)

    Figure 10: Wiring Diagram 4 Speed Motor (PSC)
  • Page 19: Figure 11: Wiring Diagram Variable Speed Motor (Ecm)

    Figure 11: Wiring Diagram Variable Speed Motor (ECM)
  • Page 20: Figure 12: Parts List With 4 Speed Motor (Psc)

    Figure 12: Parts list with 4 speed motor (PSC) B50091C...
  • Page 21: Table 10: Parts List With 4 Speed Motor (Psc)

    Table 10: Parts list with 4 speed motor (PSC) ITEM PART # DESCRIPTION COMMENTS B03622 HEAT EXCHANGER Heat exchanger only J06L002 SEAL STRIP, DIA 1/8 x 25' B03652-01 FRONT PANEL ASSEMBLY Panel, insulation and labels included B03667 FRONT PANEL INSULATION B03637-01 BAFFLE, LATERAL B03651-01...
  • Page 22: Figure 13: Parts List With Variable Speed Motor (Ecm)

    Figure 13: Parts list with variable speed motor (ECM) B50092C...
  • Page 23: Table 11: Parts List With Variable Speed Motor (Ecm)

    Table 11: Parts list with variable speed motor (ECM) ITEM PART # DESCRIPTION COMMENTS B03622 HEAT EXCHANGER Heat exchanger only J06L002 SEAL STRIP, DIA 1/8 x 25' B03652-01 FRONT PANEL ASSEMBLY (RIGHT) Panel, insulation and labels included B03667 FRONT PANEL INSULATION B03637-01 BAFFLE, LATERAL B03651-01...
  • Page 25 OBM112 Fournaise au mazout multi ---position Puissance de l’entrée 95,200---112,000 OVM112 Instructions d’installation CE MANUEL CONTIENT DES INFORMATIONS IMPORTANTES INSTALLATEUR: Utiliser l’information contenue dans ce manuel afin de procéder à l’installation de l’unité. Garder ce manuel près de l’unité pour références ultérieures. UTILISATEUR: Conserver ce manuel d’information pour références ultérieures.
  • Page 26 TABLE DES MATIÈRES RÈGLES DE SÉCURITÉ.......3 FIGURES SIGNALISATION DANGER, MISE EN GARDE ET Figure 1: Dimensions et localisation ouvertures de AVERTISSEMENT ..............3 ventilation dans la porte du placard ......5 REMARQUES IMPORTANTES .........3 SYSTÈMES DE PROTECTION ..........3 Figure 2: Débit ascendant..........5 RISQUE DE GEL ..............4 Figure 3: Débit descendant..........5 Figure 4: Débit horizontal ..........5...
  • Page 27: Règles De Sécurité

    La valve d’arrêt sur le réservoir de mazout ; 1 RÈGLES DE SÉCURITÉ iii) Le filtre d’huile sur le conduit (comment le changer une fois par année) ; iv) Le filtre à air (comment le changer, vérifier SIGNALISATION DANGER, MISE EN mensuellement et nettoyer ou changer si GARDE ET AVERTISSEMENT nécessaire) ;...
  • Page 28: Risque De Gel

    RISQUE DE GEL EMPLACEMENT AVERTISSEMENT MISE EN GARDE Si votre appareil demeure fermé durant la saison Risque d’incendie ou d'explosion. froide, les conduites d'eau peuvent geler, éclater et L’appareil doit être installé au niveau. Ne jamais provoquer des dégâts d'eau importants. Couper installer avec une inclinaison vers l’avant.
  • Page 29: Configurations

    Figure 1: Dimensions et localisation ouvertures de brûleur doit toujours être installé dans le même sens peu importe l’orientation de la fournaise. Voir figure 3 ventilation dans la porte du placard pour plus de détails. La plaque de protection (B03789) doit être installée sur le couvercle de plastique du brûleur Beckett NX afin de le protéger du tuyau d’évacuation des gaz.
  • Page 30: Raccordement Électrique

    É RACCORDEMENT LECTRIQUE Figure 6: Branchement du thermostat, chauffage et AVERTISSEMENT climatisation, unité avec moteur ECM L'extérieur de l'unité doit posséder une mise à la terre ininterrompue pour minimiser les risques de blessures corporelles jamais problème électrique se produisait. Une vis verte de mise à la terre est incluse dans la boîte de contrôle pour effectuer cette connexion.
  • Page 31: Installation Du Brûleur

    INSTALLATION DU BRÛLEUR ÉVACUATION Veuillez vous référer aux instructions fournies par le MISE EN GARDE fabriquant du brûleur pour plus de détails. Le brûleur doit toujours être installé dans le même sens peu importe Risque d’empoisonnement par monoxyde de l’orientation de la fournaise. carbone.
  • Page 32: Dispositif D'arrêt Anti-Refoulement (Bvso)

    2.6.4 Évacuation directe murale 2.8 APPROVISIONNEMENT EN AIR DE COMBUSTION ET VENTILATION L’unité de chauffage est approuvée avec un système d’évacuation directe murale. Ce système comprend un MISE EN GARDE évacuateur mural modèle VTK-54 VTK-098 KLAVT0101DET et un tuyau d’évacuation isolé de 4’’ de Risque d’empoisonnement par monoxyde de diamètre, modèle IFV-410 / IFV098-10 / KLAFV0101DET, carbone.
  • Page 33: Ventilation

    Agents chimiques pour piscine à base de chlore ; Suivre les directives d’installation de la pompe pour déterminer la dimension du conduit à utiliser en Agents chimiques adoucisseur d’eau ; fonction de l’élévation du brûleur et de la distance Sels ou agents chimiques pour le déglaçage ; horizontale à...
  • Page 34: Installation D'équipments Connexes

    Tableau 3: Ajustements des débits d'air, mode Pour faire l’ajustement, les fils ROUGE (chauffage) et BLEU climatisation (climatisation & Thermopompe) peuvent être déplacés sur le moteur. Vérifier aussi que la position des fils sur le contrôle SW2 – COOL (Climatisation) électronique de l’unité...
  • Page 35: Opération

    L’ajustement des vitesses de ventilation en 2.13.2 Filtre électronique (EAC) (Modèle PSC) chauffage et climatisation sont adéquats et selon les spécifications de ce manuel. Le terminal EAC sur le contrôle électronique de l'appareil Les délais de départ et d’arrêt du ventilateur fourni un signal 120 VAC lorsque le ventilateur fonctionne sont réglés de façon satisfaisante.
  • Page 36 3.3.2 Ajustement de la pression Ajuster le régulateur de tirage après que l'appareil ait fonctionnée au moins cinq minutes Ajuster la pression de mazout selon les spécifications et réglé entre -0.025" et -0.060" W.C. techniques de ce manuel. Une vis d’ajustement et un 3.3.5 Test de pression dessus feu emplacement pour une gauge de pression sur la pompe au...
  • Page 37: Entretien

    a pas de restrictions dans les conduits, un filtre à air Vérifier si l’interrupteur d’alimentation principal de inadéquat, une pression inadéquate dans la pompe ou la fournaise est en position ‘’ON’’ ; un calibre de gicleur inadéquat. Ajuster thermostat dessus température ambiante ;...
  • Page 38: Nettoyage De La Tête Du Brûleur

    AVERTISSEMENT REMPLACEMENT DU FILTRE À L’HUILE Ne pas érafler ou égratigner la surface de l'interrupteur thermique. Un interrupteur thermique endommagé doit Filtre du réservoir être remplacé. Remplacer le filtre du réservoir au besoin. Suivre les instructions du fabriquant. Nettoyer et enlever toute accumulation de saleté ou obstruction de l’intérieur du tube de transfert de chaleur ;...
  • Page 39: Climatisation

    Tableau 6: Spécifications techniques Modèles multi-position , Série 112 UNITÉS AVEC MOTEUR 1/2 HP 4-VIT. UNITÉS AVEC MOTEUR 1/2 HP ECM TAUX ET PERFORMANCE Allure de chauffe (USGPH)* 0,68 0,80 0,68 0,80 Consommation (BTU/h)* 95 200 112 000 95 200 112 000 Puissance de chauffage maximum (BTU/h)* 81 000...
  • Page 40: Tableau 7: Débit D'air Unités Avec Moteur 1/2 Hp Ecm.16

    Tableau 7: Débit d'air, unités avec moteur 1/2 HP ECM MODE DE CHAUFFAGE AU MAZOUT Signal 24 VAC (R) sur W seulement SW1- Chauffage ConsommationC PCM avec interrupteur PCM avec interrupteur PCM avec interrupteur Position interrupteurs hauffage DIP "SW3-ADJ", position A DIP "SW3-ADJ", position B DIP "SW3-ADJ", position C (USGPH)
  • Page 41: Tableau 8: Débit D'air Unités Avec Moteur 1/2 Hp Psc

    Tableau 8: Débit d'air (PCM), unités avec moteur 1/2 HP - PSC PRESSION ST A T IQUE EXT ERNE A V EC FIL T RE À A IR V IT ESSE 0.2" (C.E.) 0.3" (C.E.) 0.4" (C.E.) 0.5" (C.E.) 0.6" (C.E.) 0.7"...
  • Page 42 Figure 9: Dimensions de la fournaise...
  • Page 43 Figure 10: Diagramme électrique avec moteur 4 vitesses (PSC)
  • Page 44 Figure 11: Diagramme électrique avec moteur vitesse variable (ECM)
  • Page 45 Figure 12: Liste de pièces avec moteur 4 vitesses (PSC) B50091C B50091C...
  • Page 46 Tableau 10: Liste de pièces avec moteur 4 vitesses (PSC) COMMENTAIRES ITEM No DESSIN DESCRIPTION B03622 ASS ECHANGEUR CHALEUR Échangeur seulement J06L002 JOINT EXTRUDE DIA 1/8 x 25' B03652-01 ASS PANNEAU AVANT Comprend panneau, isolation et étiquettes B03667 ISOLATION PANNEAU AVANT B03637-01 DEFLECTEUR LATERAL B03651-01...
  • Page 47 Figure 13: Liste de pièces avec moteur vitesse variable (ECM) B50092C B50092C B50092C...
  • Page 48 Tableau 11: Liste de pièces avec moteur vitesse variable (ECM) COMMENTAIRES ITEM DESCRIPTION No DESSIN B03622 ASS ECHANGEUR CHALEUR Échangeur de chaleur seulement J06L002 JOINT EXTRUDE DIA 1/8 x 25' B03652-01 ASS PANNEAU AVANT Comprend panneau, isolation et étiquettes B03667 ISOLATION PANNEAU AVANT B03637-01 DEFLECTEUR LATERAL...